Testing display suitability for presenting mean-modulated flicker in clinical assessment and experimental studies of visual systems

07/22/2020
by   Luke E Hallum, et al.
0

Mean-modulated flicker – wherein luminance increments and decrements of equal magnitude are applied, over time, to a test field – is commonly used in both clinical assessment of vision and experimental studies of visual systems. However, presenting mean-modulated flicker on computer-controlled displays is problematic; displays typically introduce luminance artifacts to flickering stimuli, especially at high flicker frequency or contrast, potentially interfering with the validity of findings. Here, we present a battery of tests that we used to judge the suitability of displays for presenting mean-modulated flicker. These tests revealed marked differences between a new high-performance liquid-crystal display (LCD; EIZO ColorEdge CG247X) and a new consumer-grade LCD (Dell U2415b), despite the displays' vendor-supplied specifications being almost identical. We measured displayed luminance using a spot meter, and a linearized photodiode device to record displayed luminance waveforms. We derived spatial uniformity, response times, Fourier amplitude spectra, cycle-averaged luminance, and root-mean-squared luminance. We presented paired luminance pulses to quantify the displays' nonlinear dynamics. The CG247X showed relatively good spatial uniformity. Fourier transformation of nominally static test patches revealed spectra free of artifacts, with the exception of a frame response (artifactual flicker related to the display refresh). The CG247X's response times depended on both source and destination luminance. Despite this nonlinear behaviour, we were able to define a contrast and frequency range wherein the CG247X was artifact-free, that is, the relationship between nominal luminance and displayed luminance was accurately modelled using a causal, linear time-invariant system. This range included contrasts up to 80

READ FULL TEXT

page 1

page 2

page 3

page 4

research
12/07/2022

BiPMAP: A Toolbox for Predictions of Perceived Motion Artifacts on Modern Displays

Presenting dynamic scenes without incurring motion artifacts visible to ...
research
05/26/2023

Exploring Human Response Times to Combinations of Audio, Haptic, and Visual Stimuli from a Mobile Device

Auditory, haptic, and visual stimuli provide alerts, notifications, and ...
research
04/26/2019

Presenting Static Friction Sensation at Stick-slip Transition using Pseudo-haptic Effect

Previous studies have aimed at creating a simple hardware implementation...
research
09/06/2019

Effects of Depth Layer Switching between an Optical See-Through Head-Mounted Display and a Body-Proximate Display

Optical see-through head-mounted displays (OST HMDs) typically display v...
research
07/22/2023

On the Effectiveness of Spectral Discriminators for Perceptual Quality Improvement

Several recent studies advocate the use of spectral discriminators, whic...
research
08/21/2020

Isometric force pillow: using air pressure to quantify involuntary finger flexion in the presence of hypertonia

Survivors of central nervous system injury commonly present with spastic...
research
03/26/2018

Wavelet spectral testing: application to nonstationary circadian rhythms

Rhythmic data are ubiquitous in the life sciences. Biologists need relia...

Please sign up or login with your details

Forgot password? Click here to reset