Precise Repositioning of Robotic Ultrasound: Improving Registration-based Motion Compensation using Ultrasound Confidence Optimization

08/10/2022
by   Zhongliang Jiang, et al.
0

Robotic ultrasound (US) imaging has been seen as a promising solution to overcome the limitations of free-hand US examinations, i.e., inter-operator variability. However, the fact that robotic US systems cannot react to subject movements during scans limits their clinical acceptance. Regarding human sonographers, they often react to patient movements by repositioning the probe or even restarting the acquisition, in particular for the scans of anatomies with long structures like limb arteries. To realize this characteristic, we proposed a vision-based system to monitor the subject's movement and automatically update the scan trajectory thus seamlessly obtaining a complete 3D image of the target anatomy. The motion monitoring module is developed using the segmented object masks from RGB images. Once the subject is moved, the robot will stop and recompute a suitable trajectory by registering the surface point clouds of the object obtained before and after the movement using the iterative closest point algorithm. Afterward, to ensure optimal contact conditions after repositioning US probe, a confidence-based fine-tuning process is used to avoid potential gaps between the probe and contact surface. Finally, the whole system is validated on a human-like arm phantom with an uneven surface, while the object segmentation network is also validated on volunteers. The results demonstrate that the presented system can react to object movements and reliably provide accurate 3D images.

READ FULL TEXT

page 1

page 3

page 4

page 5

page 8

page 9

research
07/13/2021

Motion-Aware Robotic 3D Ultrasound

Robotic three-dimensional (3D) ultrasound (US) imaging has been employed...
research
07/02/2019

Inverse Problems of Trapped Objects

Optical and acoustical trapping has been established as a tool for holdi...
research
12/13/2021

RSV: Robotic Sonography for Thyroid Volumetry

In nuclear medicine, radioiodine therapy is prescribed to treat diseases...
research
01/19/2019

Endoscopic vs. volumetric OCT imaging of mastoid bone structure for pose estimation in minimally invasive cochlear implant surgery

Purpose: The facial recess is a delicate structure that must be protecte...
research
07/07/2023

Motion Magnification in Robotic Sonography: Enabling Pulsation-Aware Artery Segmentation

Ultrasound (US) imaging is widely used for diagnosing and monitoring art...
research
07/07/2023

Intelligent Robotic Sonographer: Mutual Information-based Disentangled Reward Learning from Few Demonstrations

Ultrasound (US) imaging is widely used for biometric measurement and dia...
research
06/11/2019

Design and integration of a parallel, soft robotic end-effector for extracorporeal ultrasound

In this work we address limitations in state-of-the-art ultrasound robot...

Please sign up or login with your details

Forgot password? Click here to reset