In this paper, the tools provided by the theory of Optimal Experimental Design are applied to a nonlinear calibration model. This is motivated by the need of estimating radiation doses using radiochromic films for radiotherapy purposes. The calibration model is in this case nonlinear and the explanatory variable cannot be worked out explicitly from the model. In this case an experimental design has to be found on the dependent variable. For that, the inverse function theorem will be used to obtain an information matrix to be optimized. Optimal designs on the response variable are computed from two different perspectives, first for fitting the model and estimating each of the parameters and then for predicting the proper dose to be applied to the patient. While the first is a common point of view in a general context of the Optimal Experimental Design, the latter is actually the main objective of the calibration problem for the practitioners and algorithms for computing these optimal designs are also provided.

READ FULL TEXT

page 1

page 2

page 3

page 4

research
08/02/2020

Robust Experimental Designs for Model Calibration

A computer model can be used for predicting an output only after specify...
research
11/15/2017

Bayesian optimal designs for dose-response curves with common parameters

The issue of determining not only an adequate dose but also a dosing fre...
research
12/29/2019

Effective Model Calibration via Sensible Variable Identification and Adjustment, with Application to Composite Fuselage Simulation

Estimation of model parameters of computer simulators, also known as cal...
research
04/30/2021

A Comparison of Model-Free Phase I Dose Escalation Designs for Dual-Agent Combination Therapies

It is increasingly common for therapies in oncology to be given in combi...
research
03/17/2018

Optimal Design of Nonlinear Multifactor Experiments

Most chemical and biological experiments involve multiple treatment fact...
research
12/16/2020

Optimizing the Parameters of A Physical Exercise Dose-Response Model: An Algorithmic Comparison

The purpose of this research was to compare the robustness and performan...
research
02/04/2015

Artificial neural networks in calibration of nonlinear mechanical models

Rapid development in numerical modelling of materials and the complexity...

Please sign up or login with your details

Forgot password? Click here to reset