Noncontact Haptic Rendering of Static Contact with Convex Surface Using Circular Movement of Ultrasound Focus on a Finger Pad

01/27/2023
by   Tao Morisaki, et al.
0

A noncontact tactile stimulus can be presented by focusing airborne ultrasound on the human skin. Focused ultrasound has recently been reported to produce not only vibration but also static pressure sensation on the palm by modulating the sound pressure distribution at a low frequency. This finding expands the potential for tactile rendering in ultrasound haptics as static pressure sensation is perceived with a high spatial resolution. In this study, we verified that focused ultrasound can render a static pressure sensation associated with contact with a small convex surface on a finger pad. This static contact rendering enables noncontact tactile reproduction of a fine uneven surface using ultrasound. In the experiments, four ultrasound foci were simultaneously and circularly rotated on a finger pad at 5 Hz. When the orbit radius was 3 mm, vibration and focal movements were barely perceptible, and the stimulus was perceived as static pressure. Moreover, under the condition, the pressure sensation rendered a contact with a small convex surface with a radius of 2 mm. The perceived intensity of the static contact sensation was equivalent to a physical contact force of 0.24 N on average, which was 12 times the radiation force physically applied to the skin.

READ FULL TEXT

page 1

page 2

page 3

page 4

page 7

page 8

page 10

page 12

research
11/08/2019

Sonovortex: Aerial Haptic Layer Rendering by Aerodynamic Vortex and Focused Ultrasound

In this paper, a method of rendering aerial haptics that uses an aerodyn...
research
05/16/2023

Analysis of Pleasantness Evoked by Various Airborne Ultrasound Tactile Stimuli Using Pairwise Comparisons and the Bradley-Terry Model

The presentation of a moving tactile stimulus to a person's forearm evok...
research
04/26/2019

Presenting Static Friction Sensation at Stick-slip Transition using Pseudo-haptic Effect

Previous studies have aimed at creating a simple hardware implementation...
research
04/25/2019

A pressure field model for fast, robust approximation of net contact force and moment between nominally rigid objects

We introduce an approximate model for predicting the net contact wrench ...
research
09/24/2018

BubbleTouch: A Quasi-Static Tactile Skin Simulator

We present BubbleTouch, an open source quasi-static simulator for roboti...
research
11/19/2022

Injectable Bubbles for Physiological Pressure Measurement

Microbubbles - used as contrast agents in ultrasound imaging - are impor...
research
02/07/2020

Noncontact Thermal and Vibrotactile Display Using Focused Airborne Ultrasound

In a typical mid-air haptics system, focused airborne ultrasound provide...

Please sign up or login with your details

Forgot password? Click here to reset