Automatic self-contained calibration of an industrial dual-arm robot with cameras using self-contact, planar constraints, and self-observation

12/14/2020
by   Karla Stepanova, et al.
0

We present a robot kinematic calibration method that combines complementary calibration approaches: self-contact, planar constraints, and self-observation. We analyze the estimation of the end effector parameters, joint offsets of the manipulators, calibration of the complete kinematic chain (DH parameters), and we compare our results with ground truth measurements provided by a laser tracker. Our main findings are: (1) When applying the complementary calibration approaches in isolation, the self-contact approach yields the best and most stable results. (2) All combinations of more than one approach were always superior to using any single approach in terms of calibration errors as well as the observability of the estimated parameters. Combining more approaches delivers robot parameters that better generalize to the parts of workspace not used for the calibration. (3) Sequential calibration, i.e. calibrating cameras first and then robot kinematics, is more effective than simultaneous calibration of all parameters. In real experiments, we employ two industrial manipulators mounted on a common base. The manipulators are equipped with force/torque sensors at their wrists, with two cameras attached to the robot base, and with special end effectors with fiducial markers. We collect a new comprehensive dataset for robot kinematic calibration and make it publicly available. The dataset and its analysis provide quantitative and qualitative insights that go beyond the specific manipulators used in this work and are applicable to self-contained robot kinematic calibration in general.

READ FULL TEXT

page 1

page 4

page 5

page 9

page 10

page 11

page 12

page 23

research
03/02/2018

SCALAR - Simultaneous Calibration of 2D Laser and Robot's Kinematic Parameters Using Three Planar Constraints

Industrial robots are increasingly used in various applications where th...
research
05/18/2018

Robot self-calibration using multiple kinematic chains

Proper calibration is key for the performance of every robot. Pushed by ...
research
06/07/2022

Robot Self-Calibration Using Actuated 3D Sensors

Both, robot and hand-eye calibration haven been object to research for d...
research
03/16/2018

Self-Calibration of Mobile Manipulator Kinematic and Sensor Extrinsic Parameters Through Contact-Based Interaction

We present a novel approach for mobile manipulator self-calibration usin...
research
10/27/2021

Self-Contained Kinematic Calibration of a Novel Whole-Body Artificial Skin for Human-Robot Collaboration

In this paper, we present an accelerometer-based kinematic calibration a...
research
06/11/2020

Geometric and Stiffness Modeling and Design of Calibration Experiments for the 7 dof Serial Manipulator KUKA iiwa 14 R820

The present project deals with the elastostatic modeling and calibration...
research
05/18/2019

SCALAR: Simultaneous Calibration of 2D Laser and Robot Kinematic Parameters Using Planarity and Distance Constraints

In this paper, we propose SCALAR, a calibration method to simultaneously...

Please sign up or login with your details

Forgot password? Click here to reset