The passive operating mode of the linear optical gesture sensor

12/12/2017
by   Krzysztof Czuszynski, et al.
0

The study evaluates the influence of natural light conditions on the effectiveness of the linear optical gesture sensor, working in the presence of ambient light only (passive mode). The orientations of the device in reference to the light source were modified in order to verify the sensitivity of the sensor. A criterion for the differentiation between two states: "possible gesture" and "no gesture" was proposed. Additionally, different light conditions and possible features were investigated, relevant for the decision of switching between the passive and active modes of the device. The criterion was evaluated based on the specificity and sensitivity analysis of the binary ambient light condition classifier. The elaborated classifier predicts ambient light conditions with the accuracy of 85.15 conditions, the hand pose can be detected. The achieved accuracy of the hand poses classifier trained on the data obtained in the passive mode in favorable light conditions was 98.76 of the linear gesture sensor reduces the total energy consumption by 93.34 resulting in 0.132 mA. It was concluded that optical linear sensor could be efficiently used in various lighting conditions.

READ FULL TEXT

page 2

page 3

page 5

research
09/11/2020

Lightweight assistive technology: A wearable, optical-fiber gesture recognition system

The goal of this project is to create an inexpensive, lightweight, weara...
research
10/29/2021

On-device Real-time Hand Gesture Recognition

We present an on-device real-time hand gesture recognition (HGR) system,...
research
12/05/2018

SolarGest: Ubiquitous and Battery-free Gesture Recognition using Solar Cells

We design a system, SolarGest, which can recognize hand gestures near a ...
research
05/26/2016

A Light-powered, Always-On, Smart Camera with Compressed Domain Gesture Detection

In this paper we propose an energy-efficient camera-based gesture recogn...
research
06/28/2023

Design and Evaluation of the JSI-KneExo: Active, Passive, Pneumatic, Portable Knee Exoskeleton

This paper presents a portable stand-alone pneumatic knee exoskeleton th...
research
12/16/2022

Exploring Hybrid Active-Passive RIS-Aided MEC Systems: From the Mode-Switching Perspective

Mobile edge computing (MEC) has been regarded as a promising technique t...
research
04/15/2022

Semi-supervised atmospheric component learning in low-light image problem

Ambient lighting conditions play a crucial role in determining the perce...

Please sign up or login with your details

Forgot password? Click here to reset