The Influence of Intensity Standardization on Medical Image Registration

Acquisition-to-acquisition signal intensity variations (non-standardness) are inherent in MR images. Standardization is a post processing method for correcting inter-subject intensity variations through transforming all images from the given image gray scale into a standard gray scale wherein similar intensities achieve similar tissue meanings. The lack of a standard image intensity scale in MRI leads to many difficulties in tissue characterizability, image display, and analysis, including image segmentation. This phenomenon has been documented well; however, effects of standardization on medical image registration have not been studied yet. In this paper, we investigate the influence of intensity standardization in registration tasks with systematic and analytic evaluations involving clinical MR images. We conducted nearly 20,000 clinical MR image registration experiments and evaluated the quality of registrations both quantitatively and qualitatively. The evaluations show that intensity variations between images degrades the accuracy of registration performance. The results imply that the accuracy of image registration not only depends on spatial and geometric similarity but also on the similarity of the intensity values for the same tissues in different images.

READ FULL TEXT VIEW PDF

page 8

page 9

page 10

page 12

07/12/2009

Multiresolution Elastic Medical Image Registration in Standard Intensity Scale

Medical image registration is a difficult problem. Not only a registrati...
12/11/2018

Evaluating the Impact of Intensity Normalization on MR Image Synthesis

Image synthesis learns a transformation from the intensity features of a...
03/29/2022

Image Segmentation with Adaptive Spatial Priors from Joint Registration

Image segmentation is a crucial but challenging task that has many appli...
11/11/2020

DeepSim: Semantic similarity metrics for learned image registration

We propose a semantic similarity metric for image registration. Existing...
04/20/2021

Semantic similarity metrics for learned image registration

We propose a semantic similarity metric for image registration. Existing...
11/12/2017

Robust Image Registration via Empirical Mode Decomposition

Spatially varying intensity noise is a common source of distortion in im...
04/18/2016

Most Likely Separation of Intensity and Warping Effects in Image Registration

This paper introduces a class of mixed-effects models for joint modeling...

1. Introduction

Image registration is an essential operation in a variety of medical imaging applications including disease diagnosis, longitudinal studies, data fusion, image segmentation, image guided therapy, volume reconstruction, pathology detection, and shape measurement (

[10, 23, 3]). It is the process of finding a geometric transformation between a pair of scenes, the source scene and the target scene, such that the similarity between the transformed source scene (registered source

) and target scene becomes optimum. There are many challenges in the registration of medical images. Among these, those that stem from the artifacts associated with images include the presence of noise, interpolation artifacts, intensity non-uniformities, and intensity non-standardness. Although considerable research has gone into addressing the effects of noise (

[7]), interpolation ([21, 8, 11]), and non-uniformity in image registration ([9]), little attention has been paid to study the effects of image intensity standardization/non-standardness in image registration. This aspect constitutes the primary focus of this paper.

MR image intensities do not possess a tissue specific numeric meaning even in images acquired for the same subject, on the same scanner, for the same body region, by using the same pulse sequence ([17, 4]). Not only a registration algorithm needs to capture both large and small scale image deformations, but it also has to deal with global and local image intensity variations. The lack of a standard and quantifiable interpretation of image intensities may cause the geometric relationship between homologous points in MR images to be affected considerably. Current techniques to overcome these differences/variations fall into two categories. The first class of methods uses intensity modelling and/or attempts to capture intensity differences during the registration process. The second group constitutes post processing methods that are independent of registration algorithms. Notable studies that have attempted to solve this problem within the first class are ([6, 20, 1]). While global intensity differences are modelled with a linear multiplicative term in ([1]), local intensity differences are modelled with basis functions. In ([20]), a locally affine but globally smooth transformation model has been developed in the presence of intensity variations which captures intensity variations with explicitly defined parameters. In ([6]

), intensities of one image are mapped into those of another via an adaptive transformation function. Although incorporating intensity modelling into the registration algorithms improves the accuracy, simultaneous estimation of intensity and geometric changes can be quite difficult and computationally expensive.

The papers that belong to the second group of methods are ([17, 4, 19, 12, 14]) in which a two-step method is devised for standardizing the intensity scale in such a way that for the same MRI protocol and body region, similar intensities achieve similar tissue meaning. The methods transform image intensities non-linearly so that the variation of the overall mean intensity of the MR images within the same tissue region across different studies obtained on the same or different scanners is minimized significantly. Furthermore, the computational cost of these methods is considerably small in comparison to methods belonging to the first class. Once tissue specific meanings are obtained, quantification and image analysis techniques, including registration, segmentation, and filtering, become more accurate.

The non-standardness issue was first demonstrated in ([17]) where a method was proposed to overcome this problem. The new variants of this method are studied in ([19]). Numerical tissue characterizability of different tissues is achieved by standardization and it is shown that this can significantly facilitate image segmentation and analysis in ([4, 5]). Combined effects of non-uniformity correction and standardization are studied in ([12]) and the sequence of operations to produce the best overall image quality is studied via an interplaying sequence of non-uniformity correction and standardization methods. In ([13]), an improved standardization method based on the concept of generalized scale is presented. In ([14]), the performance of standardization methods is compared with the known tissue characterizing property of magnetization transfer ratio (MTR) imaging and it is demonstrated that tissue specific intensities may help characterizing diseases.

The motivation for the research reported in this paper is the preliminary indication in ([2]) of the potential impact that intensity standardization may have on registration accuracy. Currently no published study exists that has examined how intensity non-standardness alone may affect registration. The goal of this paper is, therefore, to study the effect of non-standardness on registration in isolation. Toward this goal, first intensity non-uniformities are corrected in a set of images, and subsequently, they are standardized to yield a “clean set” of images. Different levels of non-standardness are then introduced artificially into these images which are then subjected to known levels of affine deformations. The clean set is also subjected to the same deformations. The deformed images with and without non-standardness are separately registered to clean images and the differences in their registration accuracy are quantified to express the influence of non-standardness. The underlying methods are described in Section II and the analysis results are presented in Section III. Section IV presents some concluding remarks.

2. Methods

2.1. Notations and Overview

We represent a 3D image, called scene for short, by a pair where is a finite 3D array of voxels, called scene domain of , covering a body region of the particular patient for whom image data are acquired, and is an intensity function defined on , which assigns an integer intensity value to each voxel . We assume that for all and if and only if there are no measured data for voxel .

In dealing with standardization issues, the body region and imaging protocol need to be specified. All images that are analyzed for their dependence on non-standardness for registration accuracy are assumed to come from the same body region and acquired as per the same acquisition protocol . The non-standardness phenomenon is predominant mainly in MR imaging. Hence, all image data sets considered in this paper pertain to MRI. However, the methods described here are applicable to any modality where this phenomenon occurs (such as radiography and electron microscopy).

There are six main components to the methods presented in this paper: (1) intensity non-uniformity correction, referred to simply as correction and denoted by an operator ; (2) intensity standardization denoted by an operator ; (3) an affine transformation of the scene, denoted by used for the purpose of creating mis-registered scenes; (4) introduction of artificial intensity non-standardness denoted by the operator ; (5) an affine scene transformation that is intended to register a scene with its mis-registered version; (6) evaluation methods used to quantify the goodness of scene registration.

Super scripts and are used to denote, respectively, the scenes resulting from applying correction, standardization, introduction of non-standardness, mis-registration, and registration operations to a given scene. Examples: . When a registration operation is applied to a scene , the target scene to which is registered will be evident from the context. The same notations are extended to sets of scenes. For example, if is a given set of scenes for body region and protocol , then , where

Our approach to study the effect of non-standardness on registration is as follows:

(S1) Take a set of scenes, pertaining to a fixed and , but acquired from different subjects in routine clinical settings.

(S2) Apply correction followed by standardization to the scenes in to produce the set of clean scenes. is as free from non-uniformities, and more importantly, from non-standardness, as we can practically make. As justified in ([12]), the best order and sequence of these operations to employ in terms of reducing non-uniformities and non-standardness is followed by . This is mainly because any correction operation introduces its own non-standardness.

(S3) Apply different known levels of non-standardness to the scenes in to produce the set .

(S4) Apply different known levels of affine deformations to the scenes in to form the scene set . Apply the same deformations to the clean scenes in the set to create . In this manner for any scene , we have the same scene after applying some non-standardness and the same deformation , namely .

(S5) Register each scene to and determine the required affine deformation (the subscript s indicates “standardized”). Similarly register each to and determine affine deformation (ns for “not standardized”) needed.

(S6) Analyze the deviations of and from the true applied transformation over all scenes and as a function of the applied level of non-standardness and affine deformations.

In the rest of this section, steps S1-S6 are described in detail.

S1: Data Sets
Two separate sets of image data (i.e., two sets ) are used in this study, both brain MR images of patients with Multiple Sclerosis, one of them being a T2 weighted acquisition, and the other, a proton density (PD) weighted set, with the following acquisition parameters: Fast Spin Echo sequence, 1.5T GE Signa scanner, TR=2500 msec, voxel size 0.86x0.86x3 . Each of the two sets is composed of 10 scenes. Since the two data sets for each patient are acquired in the same session with the same repetition time but by capturing different echos , the T2 and PD scenes for each patient can be assumed to be in registration.

S2. Non-uniformity Correction, Standardization
For non-uniformity correction, we use the method based on the concept of local morphometric scale called g-scale ([15]). Built on fuzzy connectedness principles, the g-scale at a voxel in a scene is the largest set of voxels fuzzily connected to in the scene such that all voxels in this set satisfy a predefined homogeneity criterion. Since the g-scale set represents a partitioning of the scene domain into fuzzy connectedness regions by using a predefined homogeneity criterion, resultant g-scale regions are locally homogeneous, and spatial contiguity of this local homogeneity is satisfied within the g-scale region.

g-scale based non-uniformity correction is performed in a few steps as follows. First, g-scale for all foreground voxels is computed. Second, by choosing the largest g-scale region, background variation is estimated. Third, a correction is applied to the entire scene by fitting a second order polynomial to the estimated background variation. These three steps are repeated iteratively until the largest g-scale region found is not significantly larger than the previous iteration’s largest g-scale region.

Standardization is a pre-processing technique which maps non-linearly image intensity gray scale into a standard intensity gray scale through a training and a transformation step. In the training step, a set of images acquired for the same body region as per the same protocol are given as input to learn histogram-specific parameters. In the transformation step, any given image for and is standardized with the estimated histogram-specific landmarks obtained from the training step. In the data sets considered for this study, and represents two different protocols, namely T2 and PD. The training and transformation steps are done separately for the two protocols.

The basic premise of standardization methods is that, in scenes acquired for a given

, certain tissue-specific landmarks can be identified on the histogram of the scenes. Therefore, by matching the landmarks, one can standardize the gray scales. Median, mode, quartiles, and deciles, and intensity values representing the mean intensity in each of the largest few g-

scale

regions have been used as landmarks. Additionally, to handle outliers, a “low” and “high” intensity value (selected typically at 0 and 99.8 percentiles) are also selected as landmarks.

In the training step, the landmarks are identified for each training scene specified for and intensities corresponding to the landmarks are mapped into an assumed standard scale. The mean values for these mapped landmark locations are computed. In the transformation step, the histogram of each given scene to be standardized is computed, and intensities corresponding to the landmarks are determined. Sections of the intensity scale of are mapped to the corresponding sections of the standard scale linearly so that corresponding landmarks of scene match the mean landmarks determined in the training step. (The length of the standard scale is chosen in such a manner that the overall mapping is always one-to-one and no two intensities in map into a single intensity on the standard scale.) Note that the overall mapping is generally not a simple linear scaling process but, indeed, a non-linear (piece-wise linear) operation; see ([17, 19]) for details. In the present study, standardization is done separately for T2 and PD scenes.

S3. Applying Non-standardness
To artificially introduce non-standardness into a clean scene , we use the idea of the inverse of the standardization mapping described in ([12]). A typical standardization mapping is shown in Figure 1. In this figure, only three landmarks are considered - “low” and “high” intensities and and the median corresponding to the foreground object. There are two linear mappings: the first from to and the second from to . denotes the standard scale. The horizontal axis denotes the non-standard input scene intensity and vertical axis indicates the standardized output scene intensity. In inverse mapping, since has already been standardized, the vertical axis can be considered as the input scene intensity, , and the horizontal axis can be considered as the output scene intensity, , where mapping the clean scene through varying the slopes and results in non-standard scenes. By using the values of and within the range of variation observed in initial standardization mappings of corrected scenes, the non-standard scene intensities can be obtained by

(1)

where converts any number y to the closest integer Y, and denotes the median intensity on the standard scale.

Figure 1. The standardization transformation function for inverse mapping with the various parameters shown.

In order to keep the number of registration experiments manageable, this simple model was used which involves only two variables and . Even so, as described later, this study entails nearly 20,000 registration experiments.

S4. Applying Affine Deformations
All components of the affine transformation - rotations about all three axes and translation, scaling, and shear in all three directions - are taken into account in creating scene sets and .

S5. Scene Registration
The algorithm that determines the affine transformation matrix by minimizing the sum of squared scene intensity differences as described in ([1]) is used in this step. A separate transformation matrix is found for registering each to , resulting in , and to , resulting in .

S6. Evaluation
Two types of tests were carried out - accuracy and consistency. The goal of the accuracy test was to determine how close the recovered registration transformations are to the known true transformations. The aim of the consistency test was to check how the observed accuracy behavior would consistently occur when different accuracy tests are conducted. In each test, two transformations and are compared by using the methodology that is described in ([18]) and summarized below. Let and be the T2 and PD scenes of any particular patient. Let and , , be the transformations obtained in Step S5 by matching to and to , respectively. In the accuracy tests, and are compared with the true (known) transformation over all levels of non-standardness and deformations that were employed. Both and are expected to be the same as . In the consistency tests, with and with are compared over all levels of non-standardness and deformations that were applied, and they are expected to be equal because PD and T2 scenes of the same patient are already in registration as described in S1. We measure the error between two transformations (in both the above scenarios) by the root-mean-squared error (RMSE) for the eight corner voxels of the box that approximately bounds the head, i.e., the volume of interest in our application.

In the accuracy test, for a given level of applied non-standardness and affine deformation, we get 20 pairs of RMSE values, each pair indicating how close and are to the true transformation

. A paired t-test is conducted to compare the accuracy of the two transformations based on RMSE values. The outcome of this test will be that either of the two transformations is more accurate than the other or there is no significant difference between the two (throughout we use

to indicate statistical significance). The set of all levels of applied deformations is divided into three groups - small, medium, large. For each of 8 levels of applied non-standardness and under each of these three groups, the number of occurrences of wins (w), losses (l) and non-significant differences (n) are counted for over . The number of wins and losses is normalized to get values in the range : , . A particular configuration of wins and losses can be identified by a point with coordinates in a win-loss triangle as in Figure 2. Large values of and small values of indicate that the performance point is closer to the point of all-wins. The following metric is used to express the “goodness” value of the configuration.

(2)
Figure 2. Mapping procedure for “goodness” value in normalized win-loss plane.

The procedure in the consistency test is similar to the above except that we have 10 pairs of RMSE values to compare and these values are obtained not by using the known true transformation but by using for and for .

3. Experimental Results

3.1. Implementation Details

3.1.1. Correction and Standardization

These operations are carried out by using the 3DVIEWNIX software ([22]). Based on the experiments in ([17, 4, 19]), minimum and maximum percentile values are set to and , respectively. In the standard scale, and are set to and . Figure 3 shows the original, corrected, and standardized (after correction) of two PD and two T2-weighted slices taken from two different studies in the first, second and third rows, respectively. The gain in the similarity of resulting image intensities for similar tissue types obtained can be readily seen.

Figure 3. Two slices from PD (first and second columns) and two slices from T2-weighted scenes (third and fourth columns) selected from two different studies before correction and standardization are displayed at default windows in the first row. Corresponding slices of the g-scale corrected scenes are shown in the second row. Clean scenes obtained after the standardization process of the corresponding corrected scenes are displayed at a standard window in the third row.

3.1.2. Adding known levels of non-standardness

We combine eight different ranges of the slopes and to introduce small, medium, and large scale non-standardness into the scenes. This means that, for each clean scene, we obtain eight scenes, one of which is the default clean scene itself, two scenes consisting of small scale non-standardness, two scenes consisting of medium scale non-standardness, and three scenes consisting of large scale non-standardness. The ranges of applied non-standardness are given in Table 1. We have arrived at these values by examining the training part of the standardization process through computing the ranges of the slopes and that are utilized in standardizing the corrected scenes. Figures 4 and 5 illustrate the process of introducing known levels of non-standardness into the clean slices of a PD and a T2-weighted scene utilized in our study. In both figures, the first display shows the original clean slice and the rest show the resulting non-standard slices.

function Range Description
Small Scale
Medium Scale
Large Scale
Table 1. Description of the different range of the slopes for introducing artificial non-standardness
Figure 4. First image in the first row is a slice of a clinical PD weighted clean scene of the brain. The other slices are obtained by adding the 7 different levels of non-standardness into the clean scene (7 different levels of non-standardness are to ). All images are displayed at the fixed gray level window chosen for the clean scene.
Figure 5. First image in the first row is a slice of a clinical T2 weighted clean scene of the brain. The other slices are obtained by adding the 7 different levels of non-standardness into the clean scene. (7 different levels of non-standardness are to ). All images are displayed at the fixed gray level window chosen for the clean scene.

3.1.3. Applying known amounts of deformation

Three different rotations (0, medium, and large angle), three translations (0, medium, and large displacement), three levels of scaling (0, medium, and large), and three levels of shearing (0, medium, and large) are combined to introduce 81 different known levels of deformation such that for all non-zero transformations, all three directions/axes are involved. Table 2 summarizes the amount of these transformations used for each axis in the three different groups.

Transformation Type Zero Medium Large
Translation pixels pixels pixels
Rotation
Scaling
Shearing
Table 2. The amount of deformations corresponding to different groups of transformations.

3.1.4. Registration

We use the scene based affine registration method made available in the SPM software ([1]). The algorithm determines the affine transformation matrix that optimally registers the two scenes by optimizing the sum of squared differences between scene intensities.

3.2. Results

For each of the 20 clean scenes in , considering the 7 different levels of non-standardness together with one level of standardness (i.e. total of 8 levels) and 3 x 3 x 3 x 3 = 81 different levels of mis-registration, there will be 8 x 81 = 648 scenes. Thus, in the accuracy test, there will be 20 x 648 = 12,960 registration experiments. In the consistency test, similarly, there will be 6,480 additional registration experiments. These additional experiments can be considered a validation for accuracy tests because they show how consistent the accuracy of the registration experiments are by using the fact that T2 and PD scenes are in registration.

The results of the comparison experiments are reported in Tables 3 and 4 for accuracy and consistency tests, respectively, for 7 sets of non-standard scenes with respect to the registration performance of clean scenes. The tables summarize the effectiveness of the registrations for each type of deformation recovered. The goodness values indicate that the ability to recover known deformations from transformed scenes is lower if intensity variations between source and target scenes are large. The goodness value for scenes with non-standardness indicates that the registration between clean scenes outperforms registration between scenes with certain levels of non-standardness and this is true only if .

Type of Non-Standardness Small Medium Large Total
1 0.8222 0.6562 0.7811
0.9400 0.8305 0.6167 0.7716
0.9369 0.7751 0.6309 0.7651
0.9318 0.7004 0.6048 0.7565
0.8806 0.6004 0.5622 0.6254
0.7565 0.5511 0.5341 0.5881
0.7447 0.5901 0.5051 0.5819
Table 3. Comparison of methods for Accuracy. The Goodness values are listed. Type of non-standardness are indicated by , and the type of affine deformations are indicated by small, medium, and large in the columns.
Type of Non-Standardness Small Medium Large Total
1.3427 0.9289 0.7423 1
1.1491 1 0.8039 0.9530
1 0.8039 0.7423 0.8417
0.8622 0.7447 0.5434 0.7062
0.9289 0.6722 0.5023 0.6934
0.8636 0.6890 0.5023 0.6722
1.0752 0.7097 0.2998 0.6468
Table 4. Comparison of methods for Consistency. The Goodness values are listed. Type of non-standardness are indicated by , and the type of affine deformations are indicated by small, medium, and large in the columns.

A strong possible reason for the better performance of clean scenes with respect to the non-standard scenes is that structural information for the same subject in different non-standardness levels is not the same. Therefore, correlations of the intensity values for each structure in the scenes may not reach the optimum to which the registration algorithm converges. Registration parameters are obtained through maximizing the similarity of two scenes, and it is well demonstrated in Tables 3 and 4 that correlation of the intensities is maximum when each structure in the scene has fixed tissue specific meaning.

Another possible reason is that the relationship between voxel intensities may be non-linear. Since the introduction of non-standardness is itself a non-linear process, the similarity function is likely to be affected by this situation in the form of local fluctuations which may even lead to not only less accurate registration results but also to the situation of the optimization process getting locked at local optima. The opposite situation may happen as well, especially for large scale deformations; the registration algorithm may easily fail regardless of the standardization level of the scenes (see Figure 6 (a) for a failing example of clean scenes). Local fluctuations in the similarity measure due to non-standardness may lead to different optimum points depending on the degree of non-standardness, some of which may even improve registration, as shown in Figure 6 (b). Although the registration algorithm did not get stuck in the latter case, the accuracy of the registration quality was not high especially in terms of translation parameters. In order to cope with possible failing examples in registration, we ran the registration algorithm with proper initial estimation of the transformation matrix rather than the default identity transformation matrix used in all experiments. Figure 6 (c) shows the registered and transformed clean scenes overlaid where fuzziness in gray scale images demonstrates the misalignment. Compared to the registration of non-standard scene in Figure 6 (a), the performance of the registration of clean scene in this example is still better when the initial estimation of transformation matrix is given as input to the registration process.

(a)        (b)          (c)

Figure 6. (a) An example of registration failure for clean scene with a large deformation. (b) An example for registration success for non-standard scene for the same amount of deformation as in the example in (a). (c) If a proper initialization matrix is given as input to the registration algorithm, clean scene registration performance becomes better than the example for non-standard scene.

Based on the fact that similarity of a pair of registered clean scenes is higher than the similarity of a pair of registered non-standard scenes, it can be deduced that substantially improved uniformity of tissue meaning between two scenes of the same subject being registered improves registration accuracy. Our experimental results demonstrate that scenes are registered better whenever the same tissues are represented by the same intensity levels.

We note that, in both tables, most of the entries are less than 1. This indicates that in both accuracy and consistency tests, the standardized scene registration task wins over the registration of non-standard scenes. Table 3 on its own does not convey any information about what the actual accuracies in the winning cases are, or about whether the win happens for T2 scenes only, PD only, or for both. The fact that a majority of the corresponding cells in these tables both indicate wins suggests that accuracy-based wins happen for both T2 and PD scenes. Conversely, a favorable value in Table 4 does not convey any information about whether the high consistency indicated also signals accuracy. Thus, accuracy and consistency are to some extent independent factors, and they together give us a more complete picture of the influence of non-standardness on registration.

4. Concluding Remarks

We described a controlled environment for determining the effects of intensity standardization on registration tasks in which the best image quality (clean scene) was established by the sequence of correction operation followed by standardization. We introduced several different levels of non-standardness into the clean scenes and performed nearly 20,000 registration experiments for small, medium and large scale deformations. We compared the registration performance of clean scenes with the performance of scenes with non-standardness and summarized the resulting goodness values. From overall accuracy and consistency test results in Tables 3 and 4, we conclude that intensity variation between scenes degrades registration performance. Having tissue specific numeric meaning in intensities maximizes the similarity of images which is the essence of the optimization procedure in registration. Standardization is therefore strongly recommended in the registration of images of patients in any longitudinal and follow up study, especially when image data come from different sites and different scanners of the same or different brands.

In this paper, we introductorily addressed the problem of the potential influence of intensity non-standardness on registration. This is indeed a small segment of the much larger full problem: Unlike the specific intra-modality (or intra protocol) registration task considered here, there are many situations in which the source and the target images may be from different modalities or protocols (e.g., CT to MRI, PET to MRI, and T1 to T2 registration etc.), and each such situation may have its own theme of non-standardness. Further, these themes may depend on the body region, the scanner, and its brand. We determined that a full consideration of these aspects was just beyond the scope of this paper. Since the sum of squared differences is one of the most appropriate similarity metrics for intra-modality registration, we focused on this metric in our study. But, clearly, more studies of this type in the more general settings mentioned above are needed.

Thus far, we controlled the computational environment via two factors: standardization and correction. A third important factor, noise, can be also embedded into the framework. It is known that correction itself introduces non-standardness into the scenes and it also enhances noise. Investigating the interrelationship between correction and noise suppression algorithms and determining the proper order for these operations has been studied recently ([16]). A question immediately arises as to how standardization affects registration accuracy for different orders of correction and noise filtering. Based on the study in ([16]), we may conclude that non-uniformity correction should precede noise suppression and that standardization should be the last operation among the three to obtain best image quality. However, it remains unclear as to how a combination of deterministic methods (standardization and correction) affects a random phenomenon like noise. It is thus important to study these three phenomena in the future on their own or in relation to how they may influence the registration process, especially in multi-center studies wherein data come from different scanners and brands of scanners.

5. Acknowledgement

This paper is presented in SPIE Medical Imaging - 2010. The complete version of this paper is published in Elsevier Pattern Recognition Letters, Vol(31), pp.315–323, 2010.

This research is partly funded by the European Commission Fp6 Marie Curie Action Programme (MEST-CT-2005-021170). The second author’s research is funded by an NIH grant EB004395.

References

  • [1] Ashburner, J., Neelin, P., Collins, D., Evans, A., Friston, K., October 1997. Incorporating prior knowledge into image registration. NeuroImage 6 (4), pp. 334–352.
  • [2] Bağcı, U., Bai, L., 2007. Multiresolution elastic medical image registration in standard intensity scale. In: SIBGRAPI ’07: Proceedings of the XX Brazilian Symposium on Computer Graphics and Image Processing (SIBGRAPI 2007), pp. 305–312.
  • [3] Brown, L. G., 1992. A survey of image registration techniques. Computer Surveys 24 (4). pp. 325–376.
  • [4] Ge, Y., Udupa, J., Nyul, L., Wei, L., Grossman, R., November 2000. Numerical tissue characterization in MS via standardization of the MR image intensity scale. Journal of Magnetic Resonance Imaging 12 (5), pp. 715–721.
  • [5]

    Zhuge, Y. and Udupa, J.K., 2009. Intensity standardization simplifies brain MR image segmentation. Computer Vision and Image Understanding 113, pp. 1095–1103.

  • [6] Guimond, A., Roche, A., Ayache, N., Meunier, J., January 2001. Three-dimensional multimodal brain warping using the demons algorithm and adaptive intensity corrections. IEEE Transactions on Medical Imaging 20 (1), pp. 58–69.
  • [7] Holden, M., Hill, D., Denton, E., Jarosz, J., Cox, T., Rohlfing, T., Goodey, J., Hawkes, D., February 2000. Voxel similarity measures for 3-d serial mr brain image registration. IEEE Transactions on Medical Imaging 19 (2), pp. 94–102.
  • [8] Ji, J., Pan, H., Liang, Z., September 2003. Further analysis of interpolation effects in mutual information-based image registration. IEEE Transactions on Medical Imaging 22 (9), pp. 1131–1140.
  • [9]

    Knops, Z., Maintz, J. B. A., Viergever, M. A., Pluim, J. P. W., June 2006. Normalized mutual information based registration using k-means clustering and shading correction. Medical Image Analysis 10 (3), pp. 432–439.

  • [10] Lester, H., Arridge, S. R., 1999. A survey of hierarchical non-linear medical image registration. Pattern Recognition (32), pp. 129–149.
  • [11] Likar, B., Pernu, F., January 2001. A hierarchical approach to elastic registration based on mutual information. Image and Vision Computing 19 (1-2), pp. 33–44.
  • [12] Madabhushi, A., Udupa, J., May 2005. Interplay between intensity standardization and inhomogeneity correction in MR image processing. IEEE Transactions on Medical Imaging 24 (5), pp. 561–576.
  • [13] Madabhushi, A., Udupa, J., 2006. New methods of MR image intensity standardization via generalized scale. Medical Physics 33 (9), pp. 3426–3434.
  • [14] Madabhushi, A., Udupa, J., Moonis, G., 2006. Comparing MR image intensity standardization against tissue characterizability of magnetization transfer ratio imaging. Journal of Magnetic Resonance Imaging 24 (3), pp. 667–675.
  • [15] Madabhushi, A., Udupa, J., Souza, A., February 2005. Generalized scale: Theory, algorithms, and application to image inhomogeneity correction. Computer Vision and Image Understanding 101 (2), pp. 100–121.
  • [16] Montillo, A., Udupa, J., Axel, L., Metaxas, D., 2003. Interaction between noise suppression and inhomogeneity correction in MRI. In: Proceedings of SPIE: Medical Imaging. Vol. 5032. pp. 1025–1036.
  • [17] Nyul, L., Udupa, J., 1999. On standardizing the MR image intensity scale. Magnetic Resonance in Medicine 42 (6), pp. 1072–1081.
  • [18] Nyul, L., Udupa, J., Saha, P., February 2003. Incorporating a measure of local scale in voxel-based 3-D image registration. IEEE Transactions on Medical Imaging 22 (2), pp. 228–237.
  • [19] Nyul, L., Udupa, J., Zhang, X., February 2000. New variants of a method of MRI scale standardization. IEEE Transactions on Medical Imaging 19 (2), pp. 143–150.
  • [20] Periaswamy, S., Farid, H., July 2003. Elastic registration in the presence of intensity variations. IEEE Transactions on Medical Imaging 22 (7), pp. 865–874.
  • [21] Pluim, J. P. W., Maintz, J. B. A., Viergever, M. A., 2000. Interpolation artifacts in mutual information-based image registration. Computer Vision and Image Understanding 77 (9), pp. 211–232.
  • [22] Udupa, J.K., Odhner, D., Samarasekera, S., Goncalves, R.J., Iyer, K., Venugopal, K.P., Furuie, S.S., 1994. 3dviewnix: An open, transportable, multidimensional, multi-modality, multi-parametric imaging software system. In: Proceedings of SPIE: Medical Imaging. Vol. 2164. pp. 58–73.
  • [23] Zitova, B., Flusser, J., October 2003. Image registration methods: A survey. Image and Vision Computing 21 (11), pp. 977–1000.
  • [24] Cocosco, C.A.,Kollokian, V., Kwan, R.K.-S., Evans, A.C., 1997. BrainWeb: Online Interface to a 3D MRI Simulated Brain Database. Neuroimage, Vol.5, No.4, part2/4, 425.