Spline Analysis of Biomarker Data Pooled From Multiple Matched/Nested Case-Control Studies

11/21/2019
by   Yujie Wu, et al.
0

Pooling biomarker data across multiple studies enables researchers to get more precise estimates of the association between biomarker exposure measurements and disease risks due to increased sample sizes. However, biomarker measurements vary significantly across different assays and laboratories, and therefore calibration of the local laboratory measurements to a reference laboratory is necessary before pooling data. We propose two methods that can estimate a nonlinear relationship between biomarker exposure measurements and disease risks using spline functions with a nested case-control study design: full calibration and internalized calibration. The full calibration method calibrates all observations using a study-specific calibration model while the internalized calibration method only calibrates observations that do not have reference laboratory measurements available. We compare the two methods with a naive method whereby data are pooled without calibration. We find that: (1) Internalized and full calibration methods have substantially better performance than the naive method in terms of average relative bias and coverage rate. (2) Full calibration is more robust than internalized calibration when the size of calibration subsets varies. We apply our methods to a pooling project with nested case-control study design to estimate the association of circulating Vitamin D levels with the risk of colorectal cancer.

READ FULL TEXT

page 1

page 2

page 3

page 4

research
06/03/2019

Statistical methods for biomarker data pooled from multiple nested case-control studies

Pooling biomarker data across multiple studies allows for examination of...
research
10/25/2021

A repeated measures approach to pooled and calibrated biomarker data

Participant level meta-analysis across multiple studies increases the sa...
research
04/06/2023

Cox model inference for relative hazard and pure risk from stratified weight-calibrated case-cohort data

The case-cohort design obtains complete covariate data only on cases and...
research
01/04/2018

A novel calibration framework for survival analysis when a binary covariate is measured at sparse time points

The goals in clinical and cohort studies often include evaluation of the...
research
05/29/2022

Extrinsic Calibration of Multiple Inertial Sensors from Arbitrary Trajectories

We present a method of extrinsic calibration for a system of multiple in...
research
10/24/2018

Local calibration of verbal autopsy algorithms

Computer-coded-verbal-autopsy (CCVA) algorithms used to generate burden-...
research
09/08/2018

On the Calibration of Nested Dichotomies for Large Multiclass Tasks

Nested dichotomies are used as a method of transforming a multiclass cla...

Please sign up or login with your details

Forgot password? Click here to reset