Simultaneous Denoising and Motion Estimation for Low-dose Gated PET using a Siamese Adversarial Network with Gate-to-Gate Consistency Learning

09/14/2020
by   Bo Zhou, et al.
12

Gating is commonly used in PET imaging to reduce respiratory motion blurring and facilitate more sophisticated motion correction methods. In the applications of low dose PET, however, reducing injection dose causes increased noise and reduces signal-to-noise ratio (SNR), subsequently corrupting the motion estimation/correction steps, causing inferior image quality. To tackle these issues, we first propose a Siamese adversarial network (SAN) that can efficiently recover high dose gated image volume from low dose gated image volume. To ensure the appearance consistency between the recovered gated volumes, we then utilize a pre-trained motion estimation network incorporated into SAN that enables the constraint of gate-to-gate (G2G) consistency. With high-quality recovered gated volumes, gate-to-gate motion vectors can be simultaneously outputted from the motion estimation network. Comprehensive evaluations on a low dose gated PET dataset of 29 subjects demonstrate that our method can effectively recover the low dose gated PET volumes, with an average PSNR of 37.16 and SSIM of 0.97, and simultaneously generate robust motion estimation that could benefit subsequent motion corrections.

READ FULL TEXT

page 7

page 8

page 13

page 14

research
04/03/2023

CG-3DSRGAN: A classification guided 3D generative adversarial network for image quality recovery from low-dose PET images

Positron emission tomography (PET) is the most sensitive molecular imagi...
research
08/24/2023

Full-dose PET Synthesis from Low-dose PET Using High-efficiency Diffusion Denoising Probabilistic Model

To reduce the risks associated with ionizing radiation, a reduction of r...
research
12/12/2017

200x Low-dose PET Reconstruction using Deep Learning

Positron emission tomography (PET) is widely used in various clinical ap...
research
10/13/2019

Parameter Constrained Transfer Learning for Low Dose PET Image Denoising

Positron emission tomography (PET) is widely used in clinical practice. ...
research
11/12/2021

Impact of loss functions on the performance of a deep neural network designed to restore low-dose digital mammography

Digital mammography is still the most common imaging tool for breast can...
research
10/31/2018

Visual Attention Network for Low Dose CT

Noise and artifacts are intrinsic to low dose CT (LDCT) data acquisition...
research
04/08/2018

DeepASL: Kinetic Model Incorporated Loss for Denoising Arterial Spin Labeled MRI via Deep Residual Learning

Arterial spin labeling (ASL) allows to quantify the cerebral blood flow ...

Please sign up or login with your details

Forgot password? Click here to reset