Signal to Noise and b-value Analysis for Optimal Intra-Voxel Incoherent Motion Imaging in the Brain

12/29/2020
by   Harri Merisaari, et al.
0

Intravoxel incoherent motion (IVIM) is a method that can provide quantitative information about perfusion in the human body, in vivo, and without contrast agent. Unfortunately, the IVIM perfusion parameter maps are known to be relatively noisy in the brain, in particular for the pseudo-diffusion coefficient, which might hinder its potential broader use in clinical applications. Therefore, we studied the conditions to produce optimal IVIM perfusion images in the brain. IVIM imaging was performed on a 3-Tesla clinical system in four healthy volunteers, with 16 b values 0, 10, 20, 40, 80, 110, 140, 170, 200, 300, 400, 500, 600, 700, 800, 900 s/mm2, repeated 20 times. We analyzed the noise characteristics of the trace images as a function of b-value, and the homogeneity of the IVIM parameter maps across number of averages and sub-sets of the acquired b values. We found two peaks of noise of the trace images as function of b value, one due to thermal noise at high b-value, and one due to physiological noise at low b-value. The selection of b value distribution was found to have higher impact on the homogeneity of the IVIM parameter maps than the number of averages. Based on evaluations, we suggest an optimal b value acquisition scheme for a 12 min scan as 0 (7), 20 (4), 140 (19), 300 (9), 500 (19), 700 (1), 800 (4), 900 (1) s/mm2.

READ FULL TEXT

page 10

page 14

page 15

research
06/01/2022

Supervised Denoising of Diffusion-Weighted Magnetic Resonance Images Using a Convolutional Neural Network and Transfer Learning

In this paper, we propose a method for denoising diffusion-weighted imag...
research
02/03/2020

Deep Learning for Highly Accelerated Diffusion Tensor Imaging

Diffusion tensor imaging (DTI) is widely used to examine the human brain...
research
06/30/2020

Accelerating Prostate Diffusion Weighted MRI using Guided Denoising Convolutional Neural Network: Retrospective Feasibility Study

Purpose: To investigate feasibility of accelerating prostate diffusion-w...
research
03/16/2020

Image Quality Transfer Enhances Contrast and Resolution of Low-Field Brain MRI in African Paediatric Epilepsy Patients

1.5T or 3T scanners are the current standard for clinical MRI, but low-f...
research
08/24/2021

Correcting inter-scan motion artefacts in quantitative R1 mapping at 7T

Purpose: Inter-scan motion is a substantial source of error in R_1 estim...
research
02/11/2020

FastPET: Near Real-Time PET Reconstruction from Histo-Images Using a Neural Network

Direct reconstruction of positron emission tomography (PET) data using d...

Please sign up or login with your details

Forgot password? Click here to reset