Sensitivity analysis of biological washout and depth selection for a machine learning based dose verification framework in proton therapy

12/21/2022
by   Shixiong Yu, et al.
0

Dose verification based on proton-induced positron emitters is a promising quality assurance tool and may leverage the strength of artificial intelligence. To move a step closer towards practical application, the sensitivity analysis of two factors needs to be performed: biological washout and depth selection. selection. A bi-directional recurrent neural network (RNN) model was developed. The training dataset was generated based upon a CT image-based phantom (abdomen region) and multiple beam energies/pathways, using Monte-Carlo simulation (1 mm spatial resolution, no biological washout). For the modeling of biological washout, a simplified analytical model was applied to change raw activity profiles over a period of 5 minutes, incorporating both physical decay and biological washout. For the study of depth selection (a challenge linked to multi field/angle irradiation), truncations were applied at different window lengths (100, 125, 150 mm) to raw activity profiles. Finally, the performance of a worst-case scenario was examined by combining both factors (depth selection: 125 mm, biological washout: 5 mins). The accuracy was quantitatively evaluated in terms of range uncertainty, mean absolute error (MAE) and mean relative errors (MRE). Our proposed AI framework shows good immunity to the perturbation associated with two factors. The detection of proton-induced positron emitters, combined with machine learning, has great potential to implement online patient-specific verification in proton therapy.

READ FULL TEXT

page 1

page 2

page 3

page 4

research
05/30/2020

Design and performance evaluation of high resolution small animal PET scanner based on monolithic crystal: a simulation study

Dedicated small-animal PET scanners functionality can be optimized by im...
research
05/11/2017

A Cascaded Convolutional Neural Network for X-ray Low-dose CT Image Denoising

Image denoising techniques are essential to reducing noise levels and en...
research
05/23/2018

Deep Learning Estimation of Absorbed Dose for Nuclear Medicine Diagnostics

The distribution of energy dose from Lu^177 radiotherapy can be estimate...
research
10/19/2020

Measuring breathing induced oesophageal motion and its dosimetric impact

Stereotactic body radiation therapy allows for a precise and accurate do...
research
07/12/2021

Evaluation of an Inflated Beam Model Applied to Everted Tubes

Everted tubes have often been modeled as inflated beams to determine tra...
research
09/10/2018

Estimate the Warfarin Dose by Ensemble of Machine Learning Algorithms

Warfarin dosing remains challenging due to narrow therapeutic index and ...

Please sign up or login with your details