Remote Photoplethysmography: Rarely Considered Factors

04/27/2020
by   Yuriy Mironenko, et al.
0

Remote Photoplethysmography (rPPG) is a fast-growing technique of vital sign estimation by analyzing video of a person. Several major phenomena affecting rPPG signals have been studied (e.g. video compression, distance from person to camera, skin tone, head motions). However, to develop a highly accurate rPPG method, new, minor, factors should be investigated. First considered factor is irregular frame rate of video recordings. Despite of PPG signal transformation by frame rate irregularity, no significant distortion of PPG signal spectra was found in the experiments. Second factor is rolling shutter effect which generates tiny phase shift of the same PPG signal in different parts of the frame caused by progressive scanning. In particular conditions effect of this artifact could be of the same order of magnitude as physiologically caused phase shifts. Third factor is a size of temporal windows, which could significantly influence the estimated error of vital sign evaluation. It follows that one should account difference in size of processing windows when comparing rPPG methods. Short series of experiments were conducted to estimate importance of these phenomena and to determine necessity of their further comprehensive study.

READ FULL TEXT
research
02/27/2015

DistancePPG: Robust non-contact vital signs monitoring using a camera

Vital signs such as pulse rate and breathing rate are currently measured...
research
08/21/2022

A Web Application for Experimenting and Validating Remote Measurement of Vital Signs

With a surge in online medical advising remote monitoring of patient vit...
research
04/26/2016

EgoSampling: Wide View Hyperlapse from Egocentric Videos

The possibility of sharing one's point of view makes use of wearable cam...
research
07/26/2021

Towards Generative Video Compression

We present a neural video compression method based on generative adversa...
research
09/29/2021

Real-Time Multi-Level Neonatal Heart and Lung Sound Quality Assessment for Telehealth Applications

Digital stethoscopes in combination with telehealth allow chest sounds t...
research
04/21/2019

Safety experiments for small robots investigating the potential of soft materials in mitigating the harm to the head due to impacts

There is a growing interest in social robots to be considered in the the...
research
03/29/2022

Neural Face Video Compression using Multiple Views

Recent advances in deep generative models led to the development of neur...

Please sign up or login with your details

Forgot password? Click here to reset