Real-Time Tilt Undersampling Optimization during Electron Tomography of Beam Sensitive Samples using Golden Ratio Scanning and RECAST3D

04/01/2023
by   Timothy M. Craig, et al.
0

Electron tomography is a widely used technique for 3D structural analysis of nanomaterials, but it can cause damage to samples due to high electron doses and long exposure times. To minimize such damage, researchers often reduce beam exposure by acquiring fewer projections through tilt undersampling. However, this approach can also introduce reconstruction artifacts due to insufficient sampling. Therefore, it is important to determine the optimal number of projections that minimizes both beam exposure and undersampling artifacts for accurate reconstructions of beam-sensitive samples. Current methods for determining this optimal number of projections involve acquiring and post-processing multiple reconstructions with different numbers of projections, which can be time-consuming and requires multiple samples due to sample damage. To improve this process, we propose a protocol that combines golden ratio scanning and quasi-3D reconstruction to estimate the optimal number of projections in real-time during a single acquisition. This protocol was validated using simulated and realistic nanoparticles, and was successfully applied to reconstruct two beam-sensitive metal-organic framework complexes.

READ FULL TEXT

page 1

page 4

page 6

page 7

page 9

page 15

page 16

page 17

research
04/04/2019

Sampling Limits for Electron Tomography with Sparsity-exploiting Reconstructions

Electron tomography (ET) has become a standard technique for 3D characte...
research
07/11/2020

Distributed optimization for nonrigid nano-tomography

Resolution level and reconstruction quality in nano-computed tomography ...
research
06/27/2017

Reduced Electron Exposure for Energy-Dispersive Spectroscopy using Dynamic Sampling

Analytical electron microscopy and spectroscopy of biological specimens,...
research
07/17/2023

Neural Modulation Fields for Conditional Cone Beam Neural Tomography

Conventional Computed Tomography (CT) methods require large numbers of n...
research
08/17/2022

Metal artifact correction in cone beam computed tomography using synthetic X-ray data

Metal artifact correction is a challenging problem in cone beam computed...
research
04/10/2023

Accelerated deep self-supervised ptycho-laminography for three-dimensional nanoscale imaging of integrated circuits

Three-dimensional inspection of nanostructures such as integrated circui...
research
02/27/2018

Reconstruction of partially sampled multi-band images - Application to STEM-EELS imaging

Electron microscopy has shown to be a very powerful tool to map the chem...

Please sign up or login with your details

Forgot password? Click here to reset