Quality-aware Cine Cardiac MRI Reconstruction and Analysis from Undersampled k-space Data

09/16/2021
by   Ines Machado, et al.
13

Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several undersampling-based reconstruction techniques have been proposed during the last decades to speed up cine cardiac MRI acquisition. However, the undersampling factor is commonly fixed to conservative values before acquisition to ensure diagnostic image quality, potentially leading to unnecessarily long scan times. In this paper, we propose an end-to-end quality-aware cine short-axis cardiac MRI framework that combines image acquisition and reconstruction with downstream tasks such as segmentation, volume curve analysis and estimation of cardiac functional parameters. The goal is to reduce scan time by acquiring only a fraction of k-space data to enable the reconstruction of images that can pass quality control checks and produce reliable estimates of cardiac functional parameters. The framework consists of a deep learning model for the reconstruction of 2D+t cardiac cine MRI images from undersampled data, an image quality-control step to detect good quality reconstructions, followed by a deep learning model for bi-ventricular segmentation, a quality-control step to detect good quality segmentations and automated calculation of cardiac functional parameters. To demonstrate the feasibility of the proposed approach, we perform simulations using a cohort of selected participants from the UK Biobank (n=270), 200 healthy subjects and 70 patients with cardiomyopathies. Our results show that we can produce quality-controlled images in a scan time reduced from 12 to 4 seconds per slice, enabling reliable estimates of cardiac functional parameters such as ejection fraction within 5

READ FULL TEXT
research
05/02/2022

A Deep Learning-based Integrated Framework for Quality-aware Undersampled Cine Cardiac MRI Reconstruction and Analysis

Cine cardiac magnetic resonance (CMR) imaging is considered the gold sta...
research
07/02/2020

Image Processing and Quality Control for Abdominal Magnetic Resonance Imaging in the UK Biobank

An end-to-end image analysis pipeline is presented for the abdominal MRI...
research
07/24/2023

Unsupervised reconstruction of accelerated cardiac cine MRI using Neural Fields

Cardiac cine MRI is the gold standard for cardiac functional assessment,...
research
01/10/2019

High Throughput Computation of Reference Ranges of Biventricular Cardiac Function on the UK Biobank Population Cohort

The exploitation of large-scale population data has the potential to imp...
research
07/18/2023

Transformer-based Dual-domain Network for Few-view Dedicated Cardiac SPECT Image Reconstructions

Cardiovascular disease (CVD) is the leading cause of death worldwide, an...
research
06/21/2022

Faster Diffusion Cardiac MRI with Deep Learning-based breath hold reduction

Diffusion Tensor Cardiac Magnetic Resonance (DT-CMR) enables us to probe...
research
03/08/2023

Reverse Engineering Breast MRIs: Predicting Acquisition Parameters Directly from Images

The image acquisition parameters (IAPs) used to create MRI scans are cen...

Please sign up or login with your details

Forgot password? Click here to reset