Projection-space implementation of deep learning-guided low-dose brain PET imaging improves performance over implementation in image-space

05/30/2020
by   Amirhossein Sanaat, et al.
0

Purpose: To assess the performance of full dose (FD) positron emission tomography (PET) image synthesis in both image and projection space from low-dose (LD) PET images/sinograms without sacrificing diagnostic quality using deep learning techniques. Methods: Clinical brain PET/CT studies of 140 patients were retrospectively employed for LD to FD PET conversion. 5% of the events were randomly selected from the FD list-mode PET data to simulate a realistic LD acquisition. A modified 3D U-Net model was implemented to predict FD sinograms in the projection-space (PSS) and FD images in image-space (PIS) from their corresponding LD sinograms/images, respectively. The quality of the predicted PET images was assessed by two nuclear medicine specialists using a five-point grading scheme. Quantitative analysis using established metrics including the peak signal-to-noise ratio (PSNR), structural similarity index metric (SSIM), region-wise standardized uptake value (SUV) bias, as well as first-, second- and high-order texture radiomic features in 83 brain regions for the test and evaluation dataset was also performed. Results: All PSS images were scored 4 or higher (good to excellent) by the nuclear medicine specialists. PSNR and SSIM values of 0.96 ± 0.03, 0.97 ± 0.02 and 31.70 ± 0.75, 37.30 ± 0.71 were obtained for PIS and PSS, respectively. The average SUV bias calculated over all brain regions was 0.24 ± 0.96% and 1.05 ± 1.44% for PSS and PIS, respectively. The Bland-Altman plots reported the lowest SUV bias (0.02) and variance (95% CI: -0.92, +0.84) for PSS compared with the reference FD images. The relative error of the homogeneity radiomic feature belonging to the Grey Level Co-occurrence Matrix category was -1.07 ± 1.77 and 0.28 ± 1.4 for PIS and PSS, respectively Conclusion: The qualitative assessment and quantitative analysis demonstrated that the FD PET prediction in projection space led to superior performance, resulting in higher image quality and lower SUV bias and variance compared to FD PET prediction in the image domain.

READ FULL TEXT

page 16

page 18

page 20

page 26

page 27

page 29

page 31

page 32

research
04/01/2021

High-quality Low-dose CT Reconstruction Using Convolutional Neural Networks with Spatial and Channel Squeeze and Excitation

Low-dose computed tomography (CT) allows the reduction of radiation risk...
research
12/07/2022

One Sample Diffusion Model in Projection Domain for Low-Dose CT Imaging

Low-dose computed tomography (CT) plays a significant role in reducing t...
research
01/22/2020

Using a Generative Adversarial Network for CT Normalization and its Impact on Radiomic Features

Computer-Aided-Diagnosis (CADx) systems assist radiologists with identif...
research
02/11/2020

FastPET: Near Real-Time PET Reconstruction from Histo-Images Using a Neural Network

Direct reconstruction of positron emission tomography (PET) data using d...
research
04/03/2023

CG-3DSRGAN: A classification guided 3D generative adversarial network for image quality recovery from low-dose PET images

Positron emission tomography (PET) is the most sensitive molecular imagi...
research
09/24/2021

A Bayesian Optimization Approach for Attenuation Correction in SPECT Brain Imaging

Photon attenuation and scatter are the two main physical factors affecti...
research
05/23/2018

Deep Learning Estimation of Absorbed Dose for Nuclear Medicine Diagnostics

The distribution of energy dose from Lu^177 radiotherapy can be estimate...

Please sign up or login with your details

Forgot password? Click here to reset