Pose Estimation of Periacetabular Osteotomy Fragments with Intraoperative X-Ray Navigation

03/22/2019
by   Robert B. Grupp, et al.
4

Objective: State of the art navigation systems for pelvic osteotomies use optical systems with external fiducials. We propose the use of X-Ray navigation for pose estimation of periacetabular fragments without fiducials. Methods: A 2D/3D registration pipeline was developed to recover fragment pose. This pipeline was tested through an extensive simulation study and 6 cadaveric surgeries. Using osteotomy boundaries in the fluoroscopic images, the preoperative plan is refined to more accurately match the intraoperative shape. Results: In simulation, average fragment pose errors were 1.3/1.7 mm when the planned fragment matched the intraoperative fragment, 2.2/2.1 mm when the plan was not updated to match the true shape, and 1.9/2.0 mm when the fragment shape was intraoperatively estimated. In cadaver experiments, the average pose errors were 2.2/2.2 mm, 3.8/2.5 mm, and 3.5/2.2 mm when registering with the actual fragment shape, a preoperative plan, and an intraoperatively refined plan, respectively. Average errors of the lateral center edge angle were less than 2 for all fragment shapes in simulation and cadaver experiments. Conclusion: The proposed pipeline is capable of accurately reporting femoral head coverage within a range clinically identified for long-term joint survivability. Significance: Human interpretation of fragment pose is challenging and usually restricted to rotation about a single anatomical axis. The proposed pipeline provides an intraoperative estimate of rigid pose with respect to all anatomical axes, is compatible with minimally invasive incisions, and has no dependence on external fiducials.

READ FULL TEXT

page 1

page 2

page 4

page 6

page 7

page 15

page 16

page 18

research
10/22/2019

Fast and Automatic Periacetabular Osteotomy Fragment Pose Estimation Using Intraoperatively Implanted Fiducials and Single-View Fluoroscopy

Accurate and consistent mental interpretation of fluoroscopy to determin...
research
09/23/2019

Patch-Based Image Similarity for Intraoperative 2D/3D Pelvis Registration During Periacetabular Osteotomy

Periacetabular osteotomy is a challenging surgical procedure for treatin...
research
07/12/2021

Evaluation of an Inflated Beam Model Applied to Everted Tubes

Everted tubes have often been modeled as inflated beams to determine tra...
research
05/16/2019

Bimodal Stereo: Joint Shape and Pose Estimation from Color-Depth Image Pair

Mutual calibration between color and depth cameras is a challenging topi...
research
03/24/2020

Automatic Modelling of Human Musculoskeletal Ligaments – Framework Overview and Model Quality Evaluation

Accurate segmentation of connective soft tissues is still a challenging ...
research
11/06/2017

SegICP-DSR: Dense Semantic Scene Reconstruction and Registration

To enable autonomous robotic manipulation in unstructured environments, ...
research
03/02/2023

Chasing Millimeters: Design, Navigation and State Estimation for Precise In-flight Marking on Ceilings

Precise markings for drilling and assembly are crucial, laborious constr...

Please sign up or login with your details

Forgot password? Click here to reset