Acceptance sampling plans offered by ISO 2859-1 are far from optimal under the conditions for statistical verification in modules F and F1 as prescribed by Annex II of the Measuring Instruments Directive (MID) 2014/32/EU, resulting in sample sizes that are larger than necessary. An optimised single-sampling scheme is derived, both for large lots using the binomial distribution and for finite-sized lots using the exact hypergeometric distribution, resulting in smaller sample sizes that are economically more efficient while offering the full statistical protection required by the MID.