Motion Corrected Multishot MRI Reconstruction Using Generative Networks with Sensitivity Encoding

02/20/2019
by   Muhammad Usman, et al.
7

Multishot Magnetic Resonance Imaging (MRI) is a promising imaging modality that can produce a high-resolution image with relatively less data acquisition time. The downside of multishot MRI is that it is very sensitive to subject motion and even small amounts of motion during the scan can produce artifacts in the final MR image that may cause misdiagnosis. Numerous efforts have been made to address this issue; however, all of these proposals are limited in terms of how much motion they can correct and the required computational time. In this paper, we propose a novel generative networks based conjugate gradient SENSE (CG-SENSE) reconstruction framework for motion correction in multishot MRI. The proposed framework first employs CG-SENSE reconstruction to produce the motion-corrupted image and then a generative adversarial network (GAN) is used to correct the motion artifacts. The proposed method has been rigorously evaluated on synthetically corrupted data on varying degrees of motion, numbers of shots, and encoding trajectories. Our analyses (both quantitative as well as qualitative/visual analysis) establishes that the proposed method significantly robust and outperforms state-of-the-art motion correction techniques and also reduces severalfold of computational times.

READ FULL TEXT

page 1

page 2

page 3

page 5

research
11/24/2018

Automating Motion Correction in Multishot MRI Using Generative Adversarial Networks

Multishot Magnetic Resonance Imaging (MRI) has recently gained popularit...
research
03/30/2023

Retrospective Motion Correction in Gradient Echo MRI by Explicit Motion Estimation Using Deep CNNs

Magnetic Resonance Imaging allows high resolution data acquisition with ...
research
10/12/2022

CoRRECT: A Deep Unfolding Framework for Motion-Corrected Quantitative R2* Mapping

Quantitative MRI (qMRI) refers to a class of MRI methods for quantifying...
research
05/17/2019

Mechanically Powered Motion Imaging Phantoms: Proof of Concept

Motion imaging phantoms are expensive, bulky and difficult to transport ...
research
10/12/2020

Assessing Lesion Segmentation Bias of Neural Networks on Motion Corrupted Brain MRI

Patient motion during the magnetic resonance imaging (MRI) acquisition p...
research
11/30/2021

Robust and Automated Method for Spike Detection and Removal in Magnetic Resonance Imaging

Radio frequency (RF) spike noise is a common source of exogenous image c...
research
08/17/2023

ICoNIK: Generating Respiratory-Resolved Abdominal MR Reconstructions Using Neural Implicit Representations in k-Space

Motion-resolved reconstruction for abdominal magnetic resonance imaging ...

Please sign up or login with your details

Forgot password? Click here to reset