Leveraging blur information for plenoptic camera calibration

11/09/2021
by   Mathieu Labussiere, et al.
0

This paper presents a novel calibration algorithm for plenoptic cameras, especially the multi-focus configuration, where several types of micro-lenses are used, using raw images only. Current calibration methods rely on simplified projection models, use features from reconstructed images, or require separated calibrations for each type of micro-lens. In the multi-focus configuration, the same part of a scene will demonstrate different amounts of blur according to the micro-lens focal length. Usually, only micro-images with the smallest amount of blur are used. In order to exploit all available data, we propose to explicitly model the defocus blur in a new camera model with the help of our newly introduced Blur Aware Plenoptic (BAP) feature. First, it is used in a pre-calibration step that retrieves initial camera parameters, and second, to express a new cost function to be minimized in our single optimization process. Third, it is exploited to calibrate the relative blur between micro-images. It links the geometric blur, i.e., the blur circle, to the physical blur, i.e., the point spread function. Finally, we use the resulting blur profile to characterize the camera's depth of field. Quantitative evaluations in controlled environment on real-world data demonstrate the effectiveness of our calibrations.

READ FULL TEXT

page 1

page 9

page 11

page 13

page 17

page 18

research
04/16/2020

Blur Aware Calibration of Multi-Focus Plenoptic Camera

This paper presents a novel calibration algorithm for Multi-Focus Plenop...
research
08/08/2023

Blur aware metric depth estimation with multi-focus plenoptic cameras

While a traditional camera only captures one point of view of a scene, a...
research
11/19/2020

Defocus Blur Detection via Salient Region Detection Prior

Defocus blur always occurred in photos when people take photos by Digita...
research
03/22/2017

Spatially-Varying Blur Detection Based on Multiscale Fused and Sorted Transform Coefficients of Gradient Magnitudes

The detection of spatially-varying blur without having any information a...
research
11/22/2022

Deblurred Neural Radiance Field with Physical Scene Priors

Neural Radiance Field(NeRF) has exhibited outstanding three-dimensional(...
research
01/02/2020

DeepFocus: a Few-Shot Microscope Slide Auto-Focus using a Sample Invariant CNN-based Sharpness Function

Autofocus (AF) methods are extensively used in biomicroscopy, for exampl...
research
12/20/2020

Geometric Scene Refocusing

An image captured with a wide-aperture camera exhibits a finite depth-of...

Please sign up or login with your details

Forgot password? Click here to reset