Improving self-calibration

12/04/2013
by   Torsten A. Enßlin, et al.
0

Response calibration is the process of inferring how much the measured data depend on the signal one is interested in. It is essential for any quantitative signal estimation on the basis of the data. Here, we investigate self-calibration methods for linear signal measurements and linear dependence of the response on the calibration parameters. The common practice is to augment an external calibration solution using a known reference signal with an internal calibration on the unknown measurement signal itself. Contemporary self-calibration schemes try to find a self-consistent solution for signal and calibration by exploiting redundancies in the measurements. This can be understood in terms of maximizing the joint probability of signal and calibration. However, the full uncertainty structure of this joint probability around its maximum is thereby not taken into account by these schemes. Therefore better schemes -- in sense of minimal square error -- can be designed by accounting for asymmetries in the uncertainty of signal and calibration. We argue that at least a systematic correction of the common self-calibration scheme should be applied in many measurement situations in order to properly treat uncertainties of the signal on which one calibrates. Otherwise the calibration solutions suffer from a systematic bias, which consequently distorts the signal reconstruction. Furthermore, we argue that non-parametric, signal-to-noise filtered calibration should provide more accurate reconstructions than the common bin averages and provide a new, improved self-calibration scheme. We illustrate our findings with a simplistic numerical example.

READ FULL TEXT

page 1

page 2

page 3

page 4

research
10/23/2014

Signal inference with unknown response: Calibration-uncertainty renormalized estimator

The calibration of a measurement device is crucial for every scientific ...
research
07/28/2021

Inferring bias and uncertainty in camera calibration

Accurate camera calibration is a precondition for many computer vision a...
research
12/21/2018

Uncertainty evalutation through data modelling for dimensional nanoscale measurements

A major bottleneck in nanoparticle measurements is the lack of comparabi...
research
09/27/2021

A Priori Calibration of Transient Kinetics Data via Machine Learning

The temporal analysis of products reactor provides a vast amount of tran...
research
05/20/2020

Sensor Networks TDOA Self-Calibration: 2D Complexity Analysis and Solutions

Given a network of receivers and transmitters, the process of determinin...
research
06/13/2021

Is Perfect Filtering Enough Leading to Perfect Phase Correction for dMRI data?

Being complex-valued and low in signal-to-noise ratios, magnitude-based ...

Please sign up or login with your details

Forgot password? Click here to reset