Fundamental bounds on the precision of iSCAT, COBRI and dark-field microscopy for 3D localization and mass photometry

06/20/2021
by   Jonathan Dong, et al.
0

Interferometric imaging is an emerging technique for particle tracking and mass photometry. Mass or position are estimated from weak signals, coherently scattered from nanoparticles or single molecules, and interfered with a co-propagating reference. In this work, we perform a statistical analysis and derive lower bounds on the measurement precision of the parameters of interest from shot-noise limited images. This is done by computing the classical Cramér-Rao bound for localization and mass estimation, using a precise vectorial model of interferometric imaging techniques. We then derive fundamental bounds valid for any imaging system, based on the quantum Cramér-Rao formalism. This approach enables a rigorous and quantitative comparison of common techniques such as interferometric scattering microscopy (iSCAT), Coherent Brightfield microscopy (COBRI), and dark-field microscopy. In particular, we demonstrate that the light collection geometry in iSCAT greatly increases the axial position sensitivity, and that the Quantum Cramér-Rao bound for mass estimation yields a minimum relative estimation error of σ_m/m=1/(2√(N)), where N is the number of collected scattered photons.

READ FULL TEXT
research
07/05/2021

DeepCEL0 for 2D Single Molecule Localization in Fluorescence Microscopy

In fluorescence microscopy, Single Molecule Localization Microscopy (SML...
research
01/07/2020

Fast and robust multiplane single molecule localization microscopy using deep neural network

Single molecule localization microscopy is widely used in biological res...
research
11/15/2019

A Molecular-MNIST Dataset for Machine Learning Study on Diffraction Imaging and Microscopy

An image dataset of 10 different size molecules, where each molecule has...
research
02/07/2023

A statistical resolution measure of fluorescence microscopy with finite photons

First discovered by Ernest Abbe in 1873, the resolution limit of a far-f...
research
12/14/2018

Single molecule localization by ℓ_2-ℓ_0 constrained optimization

Single Molecule Localization Microscopy (SMLM) enables the acquisition o...
research
06/03/2021

Limits of accuracy for parameter estimation and localisation in Single-Molecule Microscopy via sequential Monte Carlo methods

Assessing the quality of parameter estimates for models describing the m...
research
09/29/2020

Learning an optimal PSF-pair for ultra-dense 3D localization microscopy

A long-standing challenge in multiple-particle-tracking is the accurate ...

Please sign up or login with your details

Forgot password? Click here to reset