Exploring contrast generalisation in deep learning-based brain MRI-to-CT synthesis

03/17/2023
by   Lotte Nijskens, et al.
0

Background: Synthetic computed tomography (sCT) has been proposed and increasingly clinically adopted to enable magnetic resonance imaging (MRI)-based radiotherapy. Deep learning (DL) has recently demonstrated the ability to generate accurate sCT from fixed MRI acquisitions. However, MRI protocols may change over time or differ between centres resulting in low-quality sCT due to poor model generalisation. Purpose: investigating domain randomisation (DR) to increase the generalisation of a DL model for brain sCT generation. Methods: CT and corresponding T1-weighted MRI with/without contrast, T2-weighted, and FLAIR MRI from 95 patients undergoing RT were collected, considering FLAIR the unseen sequence where to investigate generalisation. A “Baseline” generative adversarial network was trained with/without the FLAIR sequence to test how a model performs without DR. Image similarity and accuracy of sCT-based dose plans were assessed against CT to select the best-performing DR approach against the Baseline. Results: The Baseline model had the poorest performance on FLAIR, with mean absolute error (MAE)=106±20.7 HU (mean±σ). Performance on FLAIR significantly improved for the DR model with MAE=99.0±14.9 HU, but still inferior to the performance of the Baseline+FLAIR model (MAE=72.6±10.1 HU). Similarly, an improvement in γ-pass rate was obtained for DR vs Baseline. Conclusions: DR improved image similarity and dose accuracy on the unseen sequence compared to training only on acquired MRI. DR makes the model more robust, reducing the need for re-training when applying a model on sequences unseen and unavailable for retraining.

READ FULL TEXT

page 5

page 8

page 15

page 16

page 28

research
08/21/2019

Improved MR to CT synthesis for PET/MR attenuation correction using Imitation Learning

The ability to synthesise Computed Tomography images - commonly known as...
research
08/22/2018

Deep Boosted Regression for MR to CT Synthesis

Attenuation correction is an essential requirement of positron emission ...
research
01/24/2019

CT synthesis from MR images for orthopedic applications in the lower arm using a conditional generative adversarial network

Purpose: To assess the feasibility of deep learning-based high resolutio...
research
05/21/2023

Generalizable synthetic MRI with physics-informed convolutional networks

In this study, we develop a physics-informed deep learning-based method ...
research
06/26/2023

Faithful Synthesis of Low-dose Contrast-enhanced Brain MRI Scans using Noise-preserving Conditional GANs

Today Gadolinium-based contrast agents (GBCA) are indispensable in Magne...
research
08/22/2020

Effects of High Iodine Containing Low Osmolar Contrast Agent (Visipaque) on Thyroid Function Tests

Objective: Investigating high iodine containing low osmolar contrast age...

Please sign up or login with your details

Forgot password? Click here to reset