Differentiable Uncalibrated Imaging

11/18/2022
by   Sidharth Gupta, et al.
0

We propose a differentiable imaging framework to address uncertainty in measurement coordinates such as sensor locations and projection angles. We formulate the problem as measurement interpolation at unknown nodes supervised through the forward operator. To solve it we apply implicit neural networks, also known as neural fields, which are naturally differentiable with respect to the input coordinates. We also develop differentiable spline interpolators which perform as well as neural networks, require less time to optimize and have well-understood properties. Differentiability is key as it allows us to jointly fit a measurement representation, optimize over the uncertain measurement coordinates, and perform image reconstruction which in turn ensures consistent calibration. We apply our approach to 2D and 3D computed tomography and show that it produces improved reconstructions compared to baselines that do not account for the lack of calibration. The flexibility of the proposed framework makes it easy to apply to almost arbitrary imaging problems.

READ FULL TEXT

page 2

page 6

page 8

page 9

page 12

research
11/26/2020

Joint Reconstruction and Calibration using Regularization by Denoising

Regularization by denoising (RED) is a broadly applicable framework for ...
research
03/09/2020

Hybrid calibration procedure for fringe projection profilometry based on stereo-vision and polynomial fitting

The key to accurate 3D shape measurement in Fringe Projection Profilomet...
research
05/09/2019

A survey of computational frameworks for solving the acoustic inverse problem in three-dimensional photoacoustic computed tomography

Photoacoustic computed tomography (PACT), also known as optoacoustic tom...
research
06/17/2021

Meta-Calibration: Meta-Learning of Model Calibration Using Differentiable Expected Calibration Error

Calibration of neural networks is a topical problem that is becoming inc...
research
05/21/2021

Automatic calibration of time of flight based non-line-of-sight reconstruction

Time of flight based Non-line-of-sight (NLOS) imaging approaches require...
research
05/16/2022

Data-Driven Interpolation for Super-Scarce X-Ray Computed Tomography

We address the problem of reconstructing X-Ray tomographic images from s...
research
11/12/2020

Disassemblable Fieldwork CT Scanner Using a 3D-printed Calibration Phantom

The use of computed tomography (CT) imaging has become of increasing int...

Please sign up or login with your details

Forgot password? Click here to reset