Clinical deployment of deep learning algorithms for chest x-ray interpretation requires a solution that can integrate into the vast spectrum of clinical workflows across the world. An appealing solution to scaled deployment is to leverage the existing ubiquity of smartphones: in several parts of the world, clinicians and radiologists capture photos of chest x-rays to share with other experts or clinicians via smartphone using messaging services like WhatsApp. However, the application of chest x-ray algorithms to photos of chest x-rays requires reliable classification in the presence of smartphone photo artifacts such as screen glare and poor viewing angle not typically encountered on digital x-rays used to train machine learning models. We introduce CheXphoto, a dataset of smartphone photos and synthetic photographic transformations of chest x-rays sampled from the CheXpert dataset. To generate CheXphoto we (1) automatically and manually captured photos of digital x-rays under different settings, including various lighting conditions and locations, and, (2) generated synthetic transformations of digital x-rays targeted to make them look like photos of digital x-rays and x-ray films. We release this dataset as a resource for testing and improving the robustness of deep learning algorithms for automated chest x-ray interpretation on smartphone photos of chest x-rays.

READ FULL TEXT VIEW PDF
POST COMMENT

Comments

There are no comments yet.

Authors

page 1

page 3

page 5

This week in AI

Get the week's most popular data science and artificial intelligence research sent straight to your inbox every Saturday.

Background & Summary

Chest x-rays are the most common imaging exams, critical for diagnosis and management of many diseases. With over 2 billion chest x-rays performed globally annually, many clinics in both developing and developed countries have an insufficient number of radiologists to perform timely x-ray interpretation [withey2019, Andronikou2011]. Computer algorithms could reduce the shortage for x-ray interpretation worldwide.

Several recent advances in training deep learning algorithms for automated chest x-ray interpretation have been made possible by large datasets [Nam2019, performance2]. In controlled settings, these deep learning algorithms can learn from data to automatically detect pathologies at an accuracy comparable to that of practicing radiologists[kallianos_ai_radiography]. These developments have been fueled both by the advancement of deep learning algorithms for image classification tasks [Huang2016, chexnext], and by the release of large public datasets [chexpert, chestxray8, bustos2019padchest, johnson2019mimiccxrjpg]. Although these advancements have demonstrated the potential of these algorithms to provide accurate chest x-ray interpretation and increase access to radiology expertise, major obstacles remain to their translation to the clinical setting [performance1, performance2].

One major obstacle to clinical adoption of chest x-ray algorithms is that clinical deployment requires a solution that can integrate into the vast spectrum of clinical workflows across the world. Most chest x-ray algorithms have been developed and validated on digital x-rays, while the vast majority of developing regions use films [mobile_teleradiology, Andronikou2011]. An appealing solution to scaled deployment is to leverage the ubiquity of existing smartphones: automated interpretation of film through cell phone photography has emerged in a “store-and-forward telemedicine” approach, in which one or more digital photos of chest films are sent as email attachments or instant messages by practitioners to obtain second opinions from specialists [xray_cell_phone, Vassallo125] as part of clinical care. Furthermore, studies have shown that photographs of films using modern phone cameras are of equivalent diagnostic quality to the films themselves [mobile_teleradiology], thus also opening up the possibility of automated algorithms for high-quality interpretation of photos of x-ray films.

Automated interpretation of photos of chest x-rays at the same high-level of performance as with digital chest x-rays is challenging because photographs of x-rays introduce visual artifacts not commonly found in digital x-rays, such as altered viewing angles, variable lighting conditions, glare, moiré, rotations, translations, and blur [adversarial_examples_world]. Image classification algorithms have been shown to experience a significant drop in performance when input images are perceived through a camera [adversarial_examples_world]. Although recent work has demonstrated good generalizability of deep learning algorithms trained on digital x-rays to photographs [chexpedition], interpretation performance could be improved through inclusion of x-ray photography in the training process [hendrycks_robustness, adversarial_explaining]. However, there are currently no large-scale public datasets of photos of chest x-rays.

To meet this need, we developed CheXphoto, a dataset of photos of chest x-rays and synthetic transformations designed to mimic the effects of photography. We believe that CheXphoto will enable effective evaluation and improvement of model robustness necessary for clinical deployment.

Figure 2: Acquiring Natural Photos of Chest X-Rays Using Automated Capture a. Visual representation of the automated picture-taking process used for Nokia10k. The steps are described: 1. X-ray retrieved from computer storage, 2. X-ray displayed on monitor, 3. X-ray index and metadata sent to phone over UDP, 4. Index verified by phone, and camera triggered, 5. Application UI updated with new picture and filename, 6. Picture saved to phone storage with metadata in filename, 7. Computer notified that imaging was successful. b. The physical setup used for Nokia10k, set in an example environment. c. Phone application UI updated with displaying last picture and save filename.

Methods

We introduce CheXphoto, a dataset of photos of chest x-rays and synthetic transformations designed to mimic the effects of photography. Specifically, CheXphoto includes a set of (1) Natural Photos: automatically and manually captured photos of x-rays under different settings, including various lighting conditions and locations, and (2) Synthetic Transformations: Targeted transformations of digital x-rays to make them look like photos of digital x-rays and x-ray films. The x-rays used in CheXphoto are sampled from CheXpert, a large dataset of 224,316 chest x-rays of 65,240 patients, with associated labels for 14 observations from radiology reports [chexpert].

CheXphoto comprises a training set of natural photos and synthetic transformations of 10,507 x-rays from 3,000 unique patients that were sampled at random from the CheXpert training set, and validation and test sets of natural and synthetic transformations to all 234 x-rays from 200 patients and 668 x-rays from 500 patients in the CheXpert validation and test sets, respectively.

Acquiring Natural Photos of Chest X-Rays

Natural photos consist of x-ray photography using cell phone cameras in various lighting conditions and environments. We developed two sets of natural photos: images captured through an automated process using a Nokia 6.1 cell phone, and images captured manually with an iPhone 8.

Automated Capture of Nokia10k dataset

We developed the ‘Nokia10k dataset’ by capturing 10,507 images of digital chest x-rays using a tripod-mounted Nokia 6.1 cell phone (16 megapixel camera with a Zeiss sensor) and a custom Android application termed CheXpeditor to fully automate the processes of photography and metadata management. The primary challenge in automation was synchronizing picture-taking on the phone with displaying the chest x-ray on the monitor, so as to maintain a 1-to-1 correspondence between each chest x-ray and its photographed image. Without a robust synchronization method, photos of chest x-rays might be skipped or duplicated, jeopardizing the data collection process. Thus, bidirectional communication over UDP was established between the picture-taking phone and the computer driving the monitor to exchange image metadata, take photos, and advance the chest x-ray on the monitor.

Pathology Positive (%) Uncertain (%) Negative (%)
No Finding 972 (9.25) 0 (0.00) 9535 (90.75)
Enlarged Cardiomediastinum 518 (4.93) 600 (5.71) 9389 (89.36)
Cardiomegaly 1313 (12.50) 370 (3.52) 8824 (83.98)
Lung Opacity 5184 (49.34) 213 (2.03) 5110 (48.63)
Lung Lesion 415 (3.95) 78 (0.74) 10014 (95.31)
Edema 2553 (24.30) 634 (6.03) 7320 (69.67)
Consolidation 671 (6.39) 1315 (12.52) 8521 (81.10)
Pneumonia 263 (2.50) 885 (8.42) 9359 (89.07)
Atelectasis 1577 (15.01) 1595 (15.18) 7335 (69.81)
Pneumothorax 957 (9.11) 166 (1.58) 9384 (89.31)
Pleural Effusion 4115 (39.16) 607 (5.78) 5785 (55.06)
Pleural Other 170 (1.62) 127 (1.21) 10210 (97.17)
Fracture 391 (3.72) 31 (0.30) 10085 (95.98)
Support Devices 5591 (53.21) 48 (0.46) 4868 (46.33)
Table 1: The distribution of labeled observations for the Nokia10k training dataset.

The 10,507 x-rays in Nokia10k were indexed deterministically from to . We selected disjoint subsets of 250 to 500 consecutive indices to be photographed in constant environmental conditions. For each subset of indices, the picture-taking was conducted as follows: 1) The th chest x-ray was retrieved from computer storage. 2) The th chest x-ray was displayed on the monitor. 3) The image metadata was assembled by the computer, and were sent to the phone via UDP. 4) The phone verified that was one greater than the previous index. If so, its camera was triggered. Else, the computer was notified of an error, and the entire picture-taking process was aborted. 5) The application UI running on the phone was updated to show the new picture and filename. 6) The picture was saved to phone storage with the metadata embedded in the filename. 7) The phone notified the computer that the imaging was successful, and the entire process was repeated for the st chest x-ray.

After all images for a Nokia10k subset were taken, they were exported in one batch from the phone to storage. The metadata was parsed from the image filenames and used to automatically assign the correct CheXpert label. Alterations made to the imaging conditions after every subset included moving to a different room, switching the room light on/off, opening/closing the window-blinds, rotating the phone orientation between portrait/landscape, adjusting the position of the tripod, moving the mouse cursor, varying the monitor’s color temperature, and switching the monitor’s screen finish between matte/glossy. In all conditions, the chest x-ray was centered in the camera view-finder and lung fields were contained within the field of view.

Manual Capture of iPhone1k dataset

We developed the ‘iPhone1k dataset’ by manually capturing 1,000 images of digital chest x-rays using an iPhone 8 camera. The digital x-rays selected for the iPhone1k dataset were a randomly sampled subset of the x-rays used in the Nokia10k dataset. To produce the iPhone1k dataset, chest x-rays were displayed in full-screen on a computer monitor with 1920 x 1080 screen resolution and a black background. A physician took photos of the chest x-rays with a handheld iPhone 8 using the standard camera app. The physician was advised to change angle and distance from the computer monitor in-between each picture within constraints.

For all images, the chest x-ray was centered in the viewfinder of the camera, and the thoracic and lung fields were contained within the field of view. Conformant to radiological chest x-ray standards, both lung-apices and costodiaphragmatic recesses were included craniocaudally, and the edges of the ribcage were included laterally. Between sets of 100 to 200 pictures, ambient alterations were made, such as switching the room-lighting on/off, opening or closing of the window-blinds, and physically moving the computer monitor to a different location in the room.

Generating Synthetic Photographic Transformations of Chest X-Rays

Synthetic transformations consist of automatic changes to the digital x-rays designed to make them look like photos of digital x-rays and x-ray films. We developed two sets of complementary synthetic transformations: digital transformations to alter contrast and brightness, and spatial transformations to add glare, moiré effects and perspective changes. To ensure that the level of these transformations did not impact the quality of the image for physician diagnosis, the images were verified by a physician. In some cases, the effects may be visually imperceptible, but may still be adversarial for classification models. For both sets, we apply the transformations to the same set of 10,507 x-rays selected for the Nokia10k dataset.

Digital transformations were produced by successive random alterations of contrast and brightness. First, the image was either enhanced for greater or lesser contrast. Setting a contrast factor of 1 for the original image, the contrast up transformation increased contrast by a factor of 1.1 and the contrast down transformation decreased contrast by a factor of 0.83. For both these factors, random noise between -0.01 and 0.01 was applied. After the contrast modification, the brightness of the image was then transformed randomly up or down using the same numeric factors. Both the brightness and contrast transformations were applied using the Python PIL ImageEnhance class.

Spatial transformations consisted of transformations to add glare, moiré effects and perspective changes. First, we applied a glare matte transformation to simulate the effect of photographing a glossy film which reflects ambient light. This was produced by randomly generating a two-dimensional multivariate normal distribution which describes the location of a circular, white mask. Next, a moiré effect was added to simulate the pattern of parallel lines seen by digital cameras when taking pictures of computer screens. The effect is produced as a result of the difference in rates of shutter speed and LCD screen sweeping refresh rate. The moiré effect was simulated by generating semi-transparent parallel lines, warping them and overlaying them onto each image. Finally, a tilt effect was added to simulate random distortions of perspective that may arise in taking a photo at angle to the screen. The tilt effect was produced by randomly scaling the

and

values of each of the corners by a factor between 0 and 0.05 towards the center. This random movement of corners is used to skew the entire photo.

(a) iPhone (b) Nokia
(c) Brightness Up (d) Brightness Down (e) Contrast Up (f) Contrast Down
(g) Glare Matte (h) Moiré (i) Tilt
Table 2: Natural Photos (a-b) and Synthetic Transformations (Digital (c-f) and Spatial (g-i)) included in CheXphoto.

Both the digital and spatial transformations are provided in CheXphoto. Each transformation may be reproduced individually using the code provided. Additional transformations - glare glossy, blur, motion, rotation, translation - are also included.

Validation and Test

We developed a CheXphoto validation and test set to be used for model validation and evaluation. The validation set comprises natural photos and synthetic transformations of all 234 x-rays in the CheXpert validation set, and is included in the public release, while the test set comprises natural photos of all 668 x-rays in the CheXpert test set, and is withheld for evaluation purposes.

We generated the natural photos of the validation set by manually capturing images of x-rays displayed on a 2560 1080 monitor using a OnePlus 6 cell phone, following a protocol that mirrored the iPhone1k dataset. The OnePlus phone has a 16 megapixel camera with a Sony IMX 519 sensor. Synthetic transformations of the validation images were produced using the same protocol as the synthetic training set. The test set was captured using an iPhone 8, following the same protocol as the iPhone1k dataset.

Data Records

Dataset Patients Studies Images Training iPhone 295 829 1,000 Nokia 3,000 8,931 10,507 Synthetic 3,000 8,931 10,507 Validation 200 200 234 Test 500 500 668
Table 3: The number of patients, studies, and images in each set of CheXphoto.
Figure 3: Example of CheXphoto directory structure

The CheXphoto dataset is organized by by transformation; the training and validation sets contain directories corresponding to the method of data generation. Within each directory, the x-ray images are organized in subdirectories by a patient identifier, study ID, and one or more individual views. Images are stored as JPEG files, and image dimensions vary according to the method of generation. Each transformation set has an associated CSV file, which provides observation labels from the CheXpert dataset and relative paths to the corresponding images.

Technical Validation

CheXphoto was developed using images and labels from the CheXpert dataset[chexpert]

. Photography of x-rays was conducted in a controlled setting in accordance with the protocols documented in the Methods section, which were developed with physician consultation. Although CheXphoto contains multiple images for some patients, either from the same or different studies, there is no patient overlap between the training, validation, and test sets. Code developed for synthetic transformations is version controlled and made available as an open source resource for review and modification.

Usage Notes

The CheXpert training and validation sets are made available for download here: https://stanfordmlgroup.github.io/competitions/chexphoto. The CheXphoto test set is withheld for official evaluation of models. CheXphoto users may submit their executable code, which is then run on the private test set, preserving the integrity of the test results. The testing process is enabled by CodaLab, an online platform for collaborative and reproducible computational research. CodaLab Worksheets exposes a simple command-line interface, which enables users to submit a Docker image, dependencies, and the necessary commands to run their models. These features allow us to run arbitrary code submissions on the withheld test set; once a user has successfully uploaded their code to CodaLab[codalab], we can evaluate their performance on the withheld test set and share results on a live leaderboard on the web.

All images are uniquely identifiable by patient ID, study ID, and view, and the age and sex of each patient is provided in the data description CSV file. The original, unaltered images can be obtained from the CheXpert dataset by the unique identifiers.

Code Availability

The code used to prepare the synthetically generated dataset is publicly available at the following link: https://github.com/stanfordmlgroup/cheXphoto. The synthetic transformations can be reproduced by running the synthesize.py script with the appropriate .csv file which contains the paths to the images for which the perturbation is applied. Detailed instructions on flags and usage are included in the repository README.

References

Author Contributions Statement

SZ, MS, and PR developed the concept and design; NAP, RK, MS, AP, NMP, CW performed acquisition, analysis, or interpretation of data; AN and MPL provided supervision. NAP, PR, MS, and RK drafted the manuscript, and all authors provided critical revision of manuscript for important intellectual content.