Blind Analysis of CT Image Noise Using Residual Denoised Images

05/24/2016
by   Sohini Roychowdhury, et al.
0

CT protocol design and quality control would benefit from automated tools to estimate the quality of generated CT images. These tools could be used to identify erroneous CT acquisitions or refine protocols to achieve certain signal to noise characteristics. This paper investigates blind estimation methods to determine global signal strength and noise levels in chest CT images. Methods: We propose novel performance metrics corresponding to the accuracy of noise and signal estimation. We implement and evaluate the noise estimation performance of six spatial- and frequency- based methods, derived from conventional image filtering algorithms. Algorithms were tested on patient data sets from whole-body repeat CT acquisitions performed with a higher and lower dose technique over the same scan region. Results: The proposed performance metrics can evaluate the relative tradeoff of filter parameters and noise estimation performance. The proposed automated methods tend to underestimate CT image noise at low-flux levels. Initial application of methodology suggests that anisotropic diffusion and Wavelet-transform based filters provide optimal estimates of noise. Furthermore, methodology does not provide accurate estimates of absolute noise levels, but can provide estimates of relative change and/or trends in noise levels.

READ FULL TEXT

page 2

page 3

research
02/18/2021

Noise Entangled GAN For Low-Dose CT Simulation

We propose a Noise Entangled GAN (NE-GAN) for simulating low-dose comput...
research
08/13/2016

Automated Selection of Uniform Regions for CT Image Quality Detection

CT images are widely used in pathology detection and follow-up treatment...
research
01/20/2020

A deep network for sinogram and CT image reconstruction

A CT image can be well reconstructed when the sampling rate of the sinog...
research
03/04/2017

Wavelet Domain Residual Network (WavResNet) for Low-Dose X-ray CT Reconstruction

Model based iterative reconstruction (MBIR) algorithms for low-dose X-ra...
research
03/23/2019

Fast LLMMSE filter for low-dose CT imaging

Low-dose X-ray CT technology is one of important directions of current r...
research
12/24/2020

Wheel-Rail Interface Condition Estimation (W-RICE)

The surface roughness between the wheel and rail has a huge influence on...
research
12/25/2015

Assessment of texture measures susceptibility to noise in conventional and contrast enhanced computed tomography lung tumour images

Noise is one of the major problems that hinder an effective texture anal...

Please sign up or login with your details

Forgot password? Click here to reset