Bayesian Deconvolution of Scanning Electron Microscopy Images Using Point-spread Function Estimation and Non-local Regularization

10/23/2018
by   Joris Roels, et al.
0

Microscopy is one of the most essential imaging techniques in life sciences. High-quality images are required in order to solve (potentially life-saving) biomedical research problems. Many microscopy techniques do not achieve sufficient resolution for these purposes, being limited by physical diffraction and hardware deficiencies. Electron microscopy addresses optical diffraction by measuring emitted or transmitted electrons instead of photons, yielding nanometer resolution. Despite pushing back the diffraction limit, blur should still be taken into account because of practical hardware imperfections and remaining electron diffraction. Deconvolution algorithms can remove some of the blur in post-processing but they depend on knowledge of the point-spread function (PSF) and should accurately regularize noise. Any errors in the estimated PSF or noise model will reduce their effectiveness. This paper proposes a new procedure to estimate the lateral component of the point spread function of a 3D scanning electron microscope more accurately. We also propose a Bayesian maximum a posteriori deconvolution algorithm with a non-local image prior which employs this PSF estimate and previously developed noise statistics. We demonstrate visual quality improvements and show that applying our method improves the quality of subsequent segmentation steps.

READ FULL TEXT

page 3

page 4

page 5

research
07/16/2023

LUCYD: A Feature-Driven Richardson-Lucy Deconvolution Network

The process of acquiring microscopic images in life sciences often resul...
research
09/16/2022

Estimation of Optical Aberrations in 3D Microscopic Bioimages

The quality of microscopy images often suffers from optical aberrations....
research
07/07/2019

Adaptive Weighting Depth-variant Deconvolution of Fluorescence Microscopy Images with Convolutional Neural Network

Fluorescence microscopy plays an important role in biomedical research. ...
research
02/07/2023

A statistical resolution measure of fluorescence microscopy with finite photons

First discovered by Ernest Abbe in 1873, the resolution limit of a far-f...
research
05/06/2007

Enhancement of Noisy Planar Nuclear Medicine Images using Mean Field Annealing

Nuclear medicine (NM) images inherently suffer from large amounts of noi...
research
07/13/2012

Deconvolution of vibroacoustic images using a simulation model based on a three dimensional point spread function

Vibro-acoustography (VA) is a medical imaging method based on the differ...

Please sign up or login with your details

Forgot password? Click here to reset