Band Target Entropy Minimization and Target Partial Least Squares for Single Target Multivariate Curve Resolution and Calibration

02/11/2018
by   Casey Kneale, et al.
0

Band target entropy minimization (BTEM) and target partial least squares calibration (T-PLS) were employed to resolve estimates for single pure component spectra and to calibrate those components concentrations in a true one-at-a-time fashion in unknown mixtures. It was found that BTEM could be used to provide spectral estimates that, when applied as the target spectra in T-PLS afforded similar errors of prediction as those from a standard multivariate curve resolution method, multivariate curve resolution alternating least squares (MCR-ALS). The calibration of BTEM resolved spectral estimates by T-PLS rather than the typical classical least squares calibration allows for the semiquantitation of individual well-represented components when other components of an unknown mixture do not have sufficient independent variation for spectral resolution. Two experimental scenarios were investigated to demonstrate situations where the combination of BTEM and T-PLS could be applied to model the pure component spectra and concentration profiles and MCR-ALS could not. The combination of both techniques are shown to resolve and calibrate a chemical impurity, melamine, by reflectance measurements of serially diluted samples of reference milk powder and of dimethyl methylphosphonate from a mid-infrared hyperspectral image of a gas stack.

READ FULL TEXT

page 18

page 19

research
02/11/2018

Band Target Entropy Minimization and Target Partial Least Squares for Spectral Recovery and Calibration

The resolution and calibration of pure spectra of minority components in...
research
10/06/2022

Unsupervised hyperspectral data mining and bioimaging by information entropy and self-modeling curve resolution

Unsupervised estimation of the dimensionality of hyperspectral microspec...
research
06/25/2021

Impact of Scene-Specific Enhancement Spectra on Matched Filter Greenhouse Gas Retrievals from Imaging Spectroscopy

Matched filter (MF) techniques have been widely used for retrieval of gr...
research
03/19/2015

Neural Network-Based Active Learning in Multivariate Calibration

In chemometrics, data from infrared or near-infrared (NIR) spectroscopy ...
research
05/29/2020

Graph-based calibration transfer

The problem of transferring calibrations from a primary to a secondary i...
research
09/19/2008

Finding rare objects and building pure samples: Probabilistic quasar classification from low resolution Gaia spectra

We develop and demonstrate a probabilistic method for classifying rare o...

Please sign up or login with your details

Forgot password? Click here to reset