Acceleration of cerebral blood flow and arterial transit time maps estimation from multiple post-labeling delay arterial spin-labeled MRI via deep learning

06/13/2022
by   Yiran Li, et al.
0

Purpose: Arterial spin labeling (ASL) perfusion imaging indicates direct and absolute measurement of cerebral blood flow (CBF). Arterial transit time (ATT) is a related physiological parameter reflecting the duration for the labeled spins to reach the brain region of interest. Multiple post-labeling delay (PLDs) can provide robust measures of both CBF and ATT, allowing for optimization of regional CBF modeling based on ATT. The prolonged acquisition time can potentially reduce the quality and accuracy of the CBF and ATT estimation. We proposed a novel network to significantly reduce the number of PLDs with higher signal-to-noise ratio (SNR). Method: CBF and ATT estimations were performed for one PLD and two PLDs sepa-rately. Each model was trained independently to learn the nonlinear transformation from perfusion weighted image (PWI) to CBF and ATT images. Results: Both one-PLD and two-PLD models outperformed the conventional method visually on CBF and two-PLD model showed more accurate structure on ATT estima-tion. The proposed method significantly reduces the number of PLDs from 6 to 2 on ATT and even to single PLD on CBF without sacrificing the SNR. Conclusion: It is feasible to generate CBF and ATT maps with reduced PLDs using deep learning with high quality.

READ FULL TEXT

page 8

page 9

research
05/15/2020

A Learning-from-noise Dilated Wide Activation Network for denoising Arterial Spin Labeling (ASL) Perfusion Images

Arterial spin labeling (ASL) perfusion MRI provides a non-invasive way t...
research
01/29/2018

Denoising Arterial Spin Labeling Cerebral Blood Flow Images Using Deep Learning

Arterial spin labeling perfusion MRI is a noninvasive technique for meas...
research
04/08/2018

DeepASL: Kinetic Model Incorporated Loss for Denoising Arterial Spin Labeled MRI via Deep Residual Learning

Arterial spin labeling (ASL) allows to quantify the cerebral blood flow ...
research
09/08/2023

A Deep Learning Method for Sensitivity Enhancement of Deuterium Metabolic Imaging (DMI)

Purpose: Common to most MRSI techniques, the spatial resolution and the ...
research
03/27/2018

Kinetic Compressive Sensing

Parametric images provide insight into the spatial distribution of physi...
research
04/08/2011

Benchmarking the Quality of Diffusion-Weighted Images

We present a novel method that allows for measuring the quality of diffu...
research
02/11/2018

Double Minimum Variance Beamforming Method to Enhance Photoacoustic Imaging

One of the common algorithms used to reconstruct photoacoustic (PA) imag...

Please sign up or login with your details

Forgot password? Click here to reset