A Surgical Platform for Intracerebral Hemorrhage Robotic Evacuation (ASPIHRE): A Non-metallic MR-guided Concentric Tube Robot

06/20/2022
by   Anthony L. Gunderman, et al.
0

Intracerebral hemorrhage (ICH) is the deadliest stroke sub-type, with a one-month mortality rate as high as 52 disruption caused by craniotomy, conservative management (watchful waiting) has historically been a common method of treatment. Minimally invasive evacuation has recently become an accepted method of treatment for patients with deep-seated hematoma 30-50 mL in volume, but proper visualization and tool dexterity remain constrained in conventional endoscopic approaches, particularly with larger hematoma volumes (> 50 mL). In this article we describe the development of ASPIHRE (A Surgical Platform for Intracerebral Hemorrhage Robotic Evacuation), the first-ever concentric tube robot that uses off-the-shelf plastic tubes for MR-guided ICH evacuation, improving tool dexterity and procedural visualization. The robot kinematics model is developed based on a calibration-based method and tube mechanics modeling, allowing the models to consider both variable curvature and torsional deflection. The MR-safe pneumatic motors are controlled using a variable gain PID algorithm producing a rotational accuracy of 0.317 +/- 0.3 degrees. The hardware and theoretical models are validated in a series of systematic bench-top and MRI experiments resulting in positional accuracy of the tube tip of 1.39 +­ 0.54 mm. Following validation of targeting accuracy, the evacuation efficacy of the robot was tested in an MR-guided phantom clot evacuation experiment. The robot was able to evacuate an initially 38.36 mL clot in 5 minutes, leaving a residual hematoma of 8.14 mL, well below the 15 mL guideline suggesting good post-ICH evacuation clinical outcomes.

READ FULL TEXT

page 1

page 4

page 5

page 7

page 12

page 14

page 15

page 16

research
06/09/2020

Resolution-Enhanced MRI-Guided Navigation of Spinal Cellular Injection Robot

This paper presents a method of navigating a surgical robot beyond the r...
research
10/23/2019

Learning Multiparametric Biomarkers for Assessing MR-Guided Focused Ultrasound Treatments Using Volume-Conserving Registration

Noninvasive MR-guided focused ultrasound (MRgFUS) treatments are promisi...
research
11/29/2022

Transcervical Ultrasound Image Guidance System for Transoral Robotic Surgery

Purpose: Trans-oral robotic surgery (TORS) using the da Vinci surgical r...
research
07/16/2020

Improving rigid 3D calibration for robotic surgery

Autonomy is the frontier of research in robotic surgery and its aim is t...
research
08/19/2021

Can a Tesla Turbine be Utilised as a Non-Magnetic Actuator for MRI-Guided Robotic Interventions?

This paper introduces a new type of nonmagnetic actuator for MRI interve...
research
01/03/2023

Safe Path following for Middle Ear Surgery

This article formulates a generic representation of a path-following con...

Please sign up or login with your details

Forgot password? Click here to reset