Low-dose computed tomography (CT) has attracted a major attention in the medical imaging field, since CT-associated x-ray radiation carries health risks for patients. The reduction of CT radiation dose, however, compromises the signal-to-noise ratio, and may compromise the image quality and the diagnostic performance. Recently, deep-learning-based algorithms have achieved promising results in low-dose CT denoising, especially convolutional neural network (CNN) and generative adversarial network (GAN). This article introduces a Contracting Path-based Convolutional Encoder-decoder (CPCE) network in 2D and 3D configurations within the GAN framework for low-dose CT denoising. A novel feature of our approach is that an initial 3D CPCE denoising model can be directly obtained by extending a trained 2D CNN and then fine-tuned to incorporate 3D spatial information from adjacent slices. Based on the transfer learning from 2D to 3D, the 3D network converges faster and achieves a better denoising performance than that trained from scratch. By comparing the CPCE with recently published methods based on the simulated Mayo dataset and the real MGH dataset, we demonstrate that the 3D CPCE denoising model has a better performance, suppressing image noise and preserving subtle structures.

READ FULL TEXT

page 7

page 8

research
04/01/2021

High-quality Low-dose CT Reconstruction Using Convolutional Neural Networks with Spatial and Channel Squeeze and Excitation

Low-dose computed tomography (CT) allows the reduction of radiation risk...
research
05/31/2021

Low-Dose CT Denoising Using a Structure-Preserving Kernel Prediction Network

Low-dose CT has been a key diagnostic imaging modality to reduce the pot...
research
02/01/2017

Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)

Given the potential X-ray radiation risk to the patient, low-dose CT has...
research
08/24/2021

DU-GAN: Generative Adversarial Networks with Dual-Domain U-Net Based Discriminators for Low-Dose CT Denoising

LDCT has drawn major attention in the medical imaging field due to the p...
research
10/13/2019

Parameter Constrained Transfer Learning for Low Dose PET Image Denoising

Positron emission tomography (PET) is widely used in clinical practice. ...
research
07/30/2018

Improving Electron Micrograph Signal-to-Noise with an Atrous Convolutional Encoder-Decoder

We present an atrous convolutional encoder-decoder trained to denoise 51...
research
11/26/2018

Low-Dose CT via Deep CNN with Skip Connection and Network in Network

A major challenge in computed tomography (CT) is how to minimize patient...

Please sign up or login with your details

Forgot password? Click here to reset