200x Low-dose PET Reconstruction using Deep Learning

12/12/2017
by   Junshen Xu, et al.
0

Positron emission tomography (PET) is widely used in various clinical applications, including cancer diagnosis, heart disease and neuro disorders. The use of radioactive tracer in PET imaging raises concerns due to the risk of radiation exposure. To minimize this potential risk in PET imaging, efforts have been made to reduce the amount of radio-tracer usage. However, lowing dose results in low Signal-to-Noise-Ratio (SNR) and loss of information, both of which will heavily affect clinical diagnosis. Besides, the ill-conditioning of low-dose PET image reconstruction makes it a difficult problem for iterative reconstruction algorithms. Previous methods proposed are typically complicated and slow, yet still cannot yield satisfactory results at significantly low dose. Here, we propose a deep learning method to resolve this issue with an encoder-decoder residual deep network with concatenate skip connections. Experiments shows the proposed method can reconstruct low-dose PET image to a standard-dose quality with only two-hundredth dose. Different cost functions for training model are explored. Multi-slice input strategy is introduced to provide the network with more structural information and make it more robust to noise. Evaluation on ultra-low-dose clinical data shows that the proposed method can achieve better result than the state-of-the-art methods and reconstruct images with comparable quality using only 0.5 regular dose.

READ FULL TEXT

page 1

page 2

page 5

page 6

research
04/01/2021

High-quality Low-dose CT Reconstruction Using Convolutional Neural Networks with Spatial and Channel Squeeze and Excitation

Low-dose computed tomography (CT) allows the reduction of radiation risk...
research
04/20/2018

DeepRec: A deep encoder-decoder network for directly solving the PET reconstruction inverse problem

Positron emission tomography (PET) is a cornerstone of modern radiology....
research
11/12/2021

Impact of loss functions on the performance of a deep neural network designed to restore low-dose digital mammography

Digital mammography is still the most common imaging tool for breast can...
research
02/11/2020

FastPET: Near Real-Time PET Reconstruction from Histo-Images Using a Neural Network

Direct reconstruction of positron emission tomography (PET) data using d...
research
08/20/2023

Contrastive Diffusion Model with Auxiliary Guidance for Coarse-to-Fine PET Reconstruction

To obtain high-quality positron emission tomography (PET) scans while re...
research
09/14/2020

Simultaneous Denoising and Motion Estimation for Low-dose Gated PET using a Siamese Adversarial Network with Gate-to-Gate Consistency Learning

Gating is commonly used in PET imaging to reduce respiratory motion blur...
research
05/01/2022

Dataset-free Deep learning Method for Low-Dose CT Image Reconstruction

Low-dose CT (LDCT) imaging attracted a considerable interest for the red...

Please sign up or login with your details

Forgot password? Click here to reset