Evaluation of Direct Haptic 4D Volume Rendering of Partially Segmented Data for Liver Puncture Simulation

05/19/2017
by   Andre Mastmeyer, et al.
0

This work presents an evaluation study using a force feedback evaluation framework for a novel direct needle force volume rendering concept in the context of liver puncture simulation. PTC/PTCD puncture interventions targeting the bile ducts have been selected to illustrate this concept. The haptic algorithms of the simulator system are based on (1) partially segmented patient image data and (2) a non-linear spring model effective at organ borders. The primary aim is to quantitatively evaluate force errors caused by our patient modeling approach, in comparison to haptic force output obtained from using gold-standard, completely manually-segmented data. The evaluation of the force algorithms compared to a force output from fully manually segmented gold-standard patient models, yields a low mean of 0.12 N root mean squared force error and up to 1.6 N for systematic maximum absolute errors. Force errors were evaluated on 31,222 preplanned test paths from 10 patients. Only twelve percent of the emitted forces along these paths were affected by errors. This is the first study evaluating haptic algorithms with deformable virtual patients in silico. We prove haptic rendering plausibility on a very high number of test paths. Important errors are below just noticeable differences for the hand-arm system.

READ FULL TEXT

page 1

page 2

page 3

page 6

page 7

page 8

page 9

page 11

research
05/18/2017

Model-based Catheter Segmentation in MRI-images

Accurate and reliable segmentation of catheters in MR-gui- ded intervent...
research
02/19/2019

A Soft High Force Hand Exoskeleton for Rehabilitation and Assistance of Spinal Cord Injury and Stroke Individuals

Individuals with spinal cord injury (SCI) and stroke who is lack of mani...
research
01/07/2020

Closed loop application of electroadhesion for increased precision in texture rendering

Tactile displays based on friction modulation offer wide-bandwidth force...
research
05/14/2021

Automated segmentation of microtomography imaging of Egyptian mummies

Propagation Phase Contrast Synchrotron Microtomography (PPC-SRμCT) is th...
research
03/28/2022

Reliability and Validity of the Polar V800 Sports Watch for Estimating Vertical Jump Height

This study aimed to assess the reliability and validity of the Polar V80...
research
05/30/2022

A multi-patient analysis of the center of rotation trajectories using finite element models of the human mandible

Studying different types of tooth movements can help us to better unders...
research
05/25/2022

Identifying Patient-Specific Root Causes with the Heteroscedastic Noise Model

Complex diseases are caused by a multitude of factors that may differ be...

Please sign up or login with your details

Forgot password? Click here to reset